| Date |
Text |
| 2004-06-24 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 04051244 |
| | ADD: 3021 OKEECHOBEE BLVD |
| | CONT: POPPER & ASSOC |
| | TEL: (561)719-7133 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | 1ST REVIW |
| | ACTION: DENIED |
| | |
| | 1) PROVIDE NOC RECORDED WITH THE CLERK |
| | OF COURT BEFORE A PERMIT CAN BE ISSUED. |
| | |
| | 2) FL BLD CODE 1804.2.2 QUESTIONABLE |
| | SOILS, WHERE THE BEARING CAPACITY IS |
| | NOT DEFINETLY KNOWN OR IS IN QUESTION. |
| | WHERE THE BEARING CAPACITY OF THE SOIL |
| | IS NOT DEFINITLY KNOWN OR IS IN QUESTION |
| | THE BUILDING OFFICIAL MAY REQUIRE EXPLOR |
| | ATIONS, TEST OR OTHER ADEQUATE PROOF AS |
| | TO THE PERMISSIBLE SAFE BEARING |
| | CAPACITY. REQUIRED TEST AND RECOMMENDA- |
| | TIONS SUBMITTED TO VERIFY BEARING CAPA- |
| | CITY SHALL BE CERTIFIED BY A GEOTECH- |
| | NICALREPORT FROM A DESIGN PROFESSIONAL |
| | PROPERLY LICENSED IN THE STATE OF |
| | FLORIDA. |
| | |
| | 3) FL BLD CODE CHAP 13 ENERGY EFFICENCY |
| | PROVIDE ENERGY CALS/ W MANUAL "J" |
| | |
| | 4) PLANS, SPECIFICATIONS,REPORTS OR |
| | OTHER DOCUMENTS PREPARED BY THE DESIGN |
| | PROFESSIONAL AND BEING FILED FOR PUBLIC |
| | RECORD SHALL HAVE THE SIGNATURE AND |
| | SEAL OF THE DESIGN PROFESSIONAL AFFIXED |
| | TO THE DOCUMENT. |
| | FL STATE STAT: 61G15-23.002 ENGINEERS |
| | FL ATATE STAT: 61G16.003 ARCHITECTS |
| | |
| | 5) FIRE DISTRICT NO TYPE VI CONSTRUCTION |
| | F102.1 WEST PALM BEACH AMENDMENT |
| | |
| | 6) A-108 DETAILS INDICATE PLYWOOD SUB- |
| | SHEATHING- NO TYPE VI CONSTRUCTION |
| | ALLOWED IN FIRE DISTRICT! |
| | |
| | 7) SITE PLAN INDICATES THE ACCESSIBLE |
| | ROUTE BETWEEN THE HUMMER SHOWROOM AND |
| | THE VW SHOWROOM AND THE PUBLIC WAY. THE |
| | PLAN ALSO INDICATES THE DROP WALK FOR AC |
| | CESSIBILITY, BUT NOT FOR THE ACCESSIBLE |
| | PARKING SPACESAND ACCESS ISLE AT THE |
| | HUMMER DEALERSHIP. |
| | |
| | 8) FL BLD CODE 1606.1.5: COMPONENTS & |
| | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| | OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| | TESTING REPORTS,MISSING REPORTS ARE AS |
| | FOLLOWS: |
| | A) SWING SERVICE DOOR, |
| | B) FIXED WINDOWS, STOREFRONT |
| | C) ROOFING STEELMASTER |
| | D) WALL LOUVERS |
| | E) STORM SHUTTERS- OVER LOUVERS A-112 |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 9) THE A-112 SHEET INDICATES STOREFRONT |
| | WINDOW OPENINGS LARGER THAN THE SUBMIT- |
| | TED REPORT. EITHER MULLION REPORTS WITH |
| | THE REQUIRED LENGTH WILL BE REQUIRED OR |
| | DIFFERENT WINDOW REPORTS. |
| | |
| | 10) THE ROOFING SYSTEM STEELMASTER |
| | BUILDINGS WILL REQUIRE EITHER PRODUCT |
| | TESTING REPORTS, (FLORIDA) OR APPROVAL |
| | THROUGH FLORIDA COMMUNITY AFFAIRS. |
| | |
| | 11) A-111 INDICATES THE USE OF "STO |
| | SYSTEM" FIRE DISTRICT NO COMBUSTIBLE |
| | ON THE EXTERIOR OF BUILDING, F102.2.7. |
| | |
| | 12) SHEET S-104 INDICATES ADDITIONAL |
| | INFORMATION TO BE SUPPLIED BY STEELMAS- |
| | TER, DECK TO BEAM CONNENCTIONS. PROVIDE |
| | ADDITIONAL INFORMATION. |
| | |
| | 13)BEFORE A PERMIT TO CONSTRUCT, MAY |
| | BE ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | LOOK FOR COMMENTS BY THE OTHER PLAN |
| | REVIEW DISCIPLINES THAT MAY BE WRITTEN |
| | ON THE APPLICATION, PLANS, OR ATTACHED |
| | SEPARATELY. WHEN RESUBMITTING PLANS |
| | PLEASE CLEARLY INDICATE THE REVISION AND |
| | REMOVE AND REPLACE ANY PAGES AS NECESS- |
| | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH |
| | THE PLANS WHEN RESUBMITTING PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN |
| | BE FOUND, WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | JIM WITMER |
| | BUILDING PLAN REVIEW |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |