| 2004-08-20 00:00:00 | DENIED |
| | |
| | 1) INCOMPLETE TITLE BLOCK INFORMATION. |
| | FAC 61G-16.004 REQUIRES THE ARCHITECT'S |
| | FIRM LICENSE NUMBER AND THE PRINTED |
| | NAME OF THE PERSON SEALING THE DOCUMENT |
| | IS REQUIRED ON EVERY SHEET. SEE FS 481. |
| | |
| | FAC 61G15-23.002 IF PRACTICING THROUGH A |
| | DULY AUTHORIZED ENGINEERING BUSINESS, |
| | ENGINEERS SHALL LEGIBLY INDICATE THEIR |
| | NAME AND LICENSE NUMBER, AS WELL AS, THE |
| | NAME, ADDRESS AND CERTIFICATE OF |
| | AUTHORIZATION NUMBER OF THE ENGINEERING |
| | BUSINESS ON EACH SHEET. SEE FS 471. |
| | |
| | 2) SHEETS A4.03, A5.03, A7.02, A7.11 AND |
| | A9.03 ARE MISSING FROM THE NEW PLAN SET. |
| | |
| | 3) PROVIDE STRUCTURAL DETAILS FOR THE |
| | CHIMNEY AT THE LOGGIA. SPECIFY THE |
| | ATTACHMENT TO ROOF, FRAMING, EXTERIOR |
| | COVERING, ETC. SHOW COMPLIANCE WITH |
| | FBC 2804.2.4 WHICH REQUIRES CHIMNEY TO |
| | BE 3 FEET ABOVE THE HIGHEST POINT THAT |
| | IT PASSES THROUGH THE ROOF AND AT LEAST |
| | 2 FEET HIGHER THAN ANY PORTION OF THE |
| | ROOF OR BUILDING WITHIN 10 FEET. |
| | |
| | 4) SUBMIT AN ADDITIONAL COPY OF THE |
| | SITE SPECIFIC PRODUCT APPROVAL. THE NOA |
| | NUMBER LISTED ON THE SHEET ATTACHED TO |
| | THE SITE SPECIFIC FORM FOR THE FRENCH |
| | DOORS IS THE OLD NUMBER. PLEASE SPECIFY |
| | THE CURRENT NOA NUMBER. |
| | |
| | 5) SPECIFY THE FIREBLOCKING AT THE |
| | CONCEALED SPACE BETWEEN STAIR STRINGERS |
| | AT THE TOP AND BOTTOM OF RUNS AS |
| | REQUIRED BY FBC 2305.1.4(3). |
| | |
| | 6) SPECIFY THE LOCATION AND MATERIAL FOR |
| | THE DRAFTSTOPPING AT THE FLOOR/CEILING |
| | ASSEMBLY DIVIDING IT INTO APPROXIMATELY |
| | 500 SQFT AREAS PER FBC 2305.2.2. |
| | |
| | 7)SUBMIT STATE OR LOCAL PRODUCT APPROVAL |
| | FOR THE FOLLOWING: |
| | - DOUBLE HUNG WINDOWS (IMPACT) |
| | - FIXED WINDOWS (IMPACT) |
| | - 8 PANEL DOOR TO LAWN STORAGE |
| | - OVERHEAD GARAGE DOORS |
| | COORDINATE THE PRODUCT APPROVALS THAT |
| | ARE SUBMITTED WITH THE WINDOWS AND DOORS |
| | THAT ARE SPECIFIED IN THE SCHEDULES ON |
| | THE PLANS. THEY NEED TO CORRESPOND TO |
| | EACH OTHER. |
| | |
| | 8) THE NEW PLANS AND PRODUCT APPROVALS |
| | ARE REQUIRED TO BE REVIEWED BY THE |
| | HISTORIC PRESERVATION DEPARTMENT. |
| | |