| Plan Review Notes For Permit 04051102 |
| Permit Number |
04051102 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2004-06-11 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SHEET S2 PROVIDES DESIGN | | | INFORMATION (STRUCTURAL NOTES) WHICH | | | RELATE TO WIND.PROVIDE DESIGN | | | CRITERIA FOR THE STAIRS (TABLE 1604.1), | | | HANDRAILS (FBC1608.2.1), AND THE | | | GUARDRAILS (FBC1608.2.2). | | | | | | 2.)RISERS SHALL BE A MAXIMUM HEIGHT OF | | | 7", MINIMUM OF 4", TREADS A MINIMUM OF | | | 11", FBC1007.3. | | | | | | 3.)HANDRAILS SHALL COMPLY WITH FBC | | | 1007.5.5. | | | | | | 4.)THE GUARDRAILS, INCLUDING THE STAIR | | | RAIL WHICH ALSO SERVES AS A GUARDRAIL, | | | ARE TO COMPLY WITH FBC1015.3 AND | | | 1015.3(1) (OPENINGS). | | | | | | 5.)THE NOTE ON DETAIL B-S4, GRAB BAR | | | RAIL SEE DETAIL, AND NEW STAIR HANDRAIL | | | POINT TO RAILS AT 42", BUT THE DETAIL | | | INDICATES 36". | | | | | | 6.)DETAIL 4-S5 REFERS TO DETAILS 7-S4 | | | AND 6-S4, DETAILS ARE ON S5. |
|