2004-08-03 00:00:00BUILDING REVIEW PROVISO:
 PROVIDE ALL INFORMATION PRIOR TO INSTA-
 LLATION TO AVOID DELAYS OR CONFLICTS)
  
 1-SPECIFY UL LISTED ASSEMBLY FOR ONE HR
 FIRE RATED GLASS BLOCK ASSEMBLY TO BE
 USED AND REVISE GLASS BLOCK DETAIL ON
 SHEET A4 TO MATCH SUCH ASSEMBLY. TABLE
 600 FBC 2001 AND SECTION 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 2-SOIL TEST REPORT TO HAVE ENGINEER'S
 ORIGINAL SIGNATURE & DATE AS REQUIRED
 BY CHAPTER 471 FLORIDA STATUTES.
 3-PRODUCT APPROVAL FOR FIXED WINDOW:
 A)PROVIDE LEGIBLE DRAWINGS.
 B)CLEARLY INDICATE ON PLANS WINDOWS TO
 HAVE TEMPERED GLASS, SINCE ACCORDING
 TO PRODUCT APPROVAL THEY ARE THE ONLY
 ONES TO MEET THE DESIGN PRESSURES
 CALCULATED ON MOST OF THE OPENINGS.
 C)NEED PRODUCT APPROVAL FOR LARGER
 WINDOWS AS SHOWN ON PLANS. SEE PRODUCT
 FOR MAX. WIDTH AND HEIGHT ALLOWED.
 4-IF OUTSWING FRENCH DOORS WILL BE USED,
 THEN REVISE PLANS TO MATCH ACCORDINGLY
 5-PROVIDE PRODUCT APPROVAL FOR MULLION
 TO BE USED FOR SLIDING GLASS DOORS W/
 TRANSOM ASSEMBLY. CLEARLY INDICATE
 MULLION SIZES & FASTENERS TO BE USED.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 6-NEED PRODUCT APPROVAL FOR ENTRY DOOR.
 7-NEED PRODUCT APPROVAL FOR STRUCTURAL
 CONNECTORS USED ON THIS PROJECT.
 8-STORM SHUTTERS: REVISE KEY PLAN AND
 INSTALLATION SCHEDULE TO SHOW EGRESS
 OPENING REQUIRED BY SEC. 1005.4.5 FBC.
 9-TRUSS DRAWINGS PACKAGE: A)ENGINEER TO
 PROVIDE ORIGINAL SIGNATURE AS REQUIRED
 BY CHAPTER 471 FLORIDA STATUTES.
 B)ENGINEER OF RECORD TO REVIEW & APPROVE
 THEM PRIOR TO SUBMITTAL.
 10-SHEET A4 AND S3 SHOW DIFFERENT SPECS
 FOR WINDOW & DOOR BUCKS. SPECIFY WHICH
 SPECS WILL BE USED.
 11-SHEET A5 AND S3. REVISE ALL NOTES.SEE
 CHAPTER 19 & 35 FOR SPECIFIC REFERENCE
 STANDARD AND EDITION TO BE REFERENCED
 ACCORDING TO FBC 2001.
 12-CONNECTOR SPECIFIED FOR TRUSSES AT
 ATRIUM AREA DON'T RESIST CALCULATED
 LOADS. SEE ENGINEERED TRUSSES FOR
 UPLIFT LOADS AND BEARING POINTS AND
 REVISE CONNECTOR AS REQUIRED.
 13-HANGER HU614 IS FOR WOOD TO WOOD
 CONNECTIONS. SPECIFY WOOD TO MASONRY
 HANGER AND SPECIFY FASTENERS. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 14-CONNECTOR SPECIFIED FOR TRUSSES AT
 REAR PORCH NEED TO BE WOOD TO WOOD.
 CONNECTOR SPECIFIED IS TO BE EMBEDED
 IN CONCRETE. REVISE AS REQUIRED. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC.
 15-WINDOWS AT DINING AREA TO BE SAFETY
 GLASS AS REQ'D BY SEC. 2405.2.1(4)FBC.