2004-06-15 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) FILTERS MUST MEET THE REQUIREMENTS OF
 NSF 42. SUBMIT MANUF. SPECIFICATIONS
 SHOWING COMPLIANCE. SECTION 611.1.
 2) SHTS P2.0 & P3.0 SUBMIT A SANITARY &
 A WATER RISER DIAGRAM IN ISOMETRIC FORM.
 SHOW ALL PIPE SIZES, WATER HAMMER ARRES-
 TORS REQUIRED BY SECTION 604.9 LOCATED
 IN ACCORDANCE WITH PDI-WH 201. RISER
 DIAGRAMS SHALL REFLECT THE FLOOR PLAN &
 ACTUAL INSTALLATION. SECTION 104.3.1.1.
 3) SHTS P2.0 & P3.0 PLUMBING SUPPLY PLAN
 NOTES #2 INDICATE THE WATER HEATER SHALL
 BE INSTALLED OVER THE MOP SINK. DETAIL
 #2 SHOWS THE SAME. FLOOR PLAN SHOW MOP
 SINK AND WATER HEATER IN DIFFERENT LOCA-
 TIONS. PLEASE CLARIFY, CORRELATE PLANS.
 SECTION 104.2.1.
 4) SHT P2.0 PLUMBING SCHEDULE: UNABLE TO
 LOCATE P047 FLOOR DRAIN, P360 FAUCET,
 P801 DRAIN GRAT, ADL 6 ICE BIN, ADL 7
 DIPPER WELL & ADL 8 WATER TOWER ON LAY-
 OUT FLOOR PLAN. PLEASE CLARIFY, CORRELA-
 TE PLANS. - INDICATE TYPE OF FIXTURE
 ADL 10 IS. NOT SHOWN ON SCHEDULE. SECT-
 ION 104.2.1/
 4) PROFESSIONAL ENGINEER SHALL SIGN HIS
 NAME AND AFFIX HIS SEAL TO ALL PLANS,
 SPECIFICATIONS, REPORTS AND FINAL BID
 DOCUMENTS PROVIDED TO THE OWNER OR THE
 OWNER'S REPRESENTATIVE, OR OTHER DOCU-
 MENTS PREPARED OR ISSUED BY SAID REGIS-
 TRANT AND BEING FILED FOR PUBLIC RECORD.
 THE DATE THAT THE SIGNATURE AND SEAL IS
 AFFIXED AS PROVIDED HEREIN SHALL BE EN-
 TERED ON SAID PLANS, SPECIFICATIONS, RE-
 PORTS, OR OTHER DOCUMENTS IMMEDIATELY
 UNDER THE SIGNATURE OF THE PROFESSIONAL
 ENGINEER, FAC 61G15-23.002(1)
 FS 471.025
 EACH SHEET OF PLANS AND PRINTS WHICH
 MUST BE SEALED UNDER THE PROVISIONS OF
 CHAPTER 471 SHALL BE SEALED, SIGNED AND
 DATED BY THE PROFESSIONAL ENGINEER IN
 RESPONSIBLE CHARGE. FAC 61G15-23.002(2)
 FS 471.025
 ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]