| Date |
Text |
| 2005-02-01 00:00:00 | ************** UNSAT **************** |
| | |
| | 1)NOTE: PLEASE SEE AN EQUIPMENT |
| | GROUNDING CONDUCTOR IS SHOWN FROM METER |
| | TO MAIN/PANEL "B". PLEASE SEE |
| | 250.6,250.24. EQP GRND IS ONLY INSTALLED |
| | AFTER THE FIRST MEANS OF DISC. |
| | |
| | 2)NOTE: PLEASE SEE |
| | 210.11C1,210.52B,220.16, SMALL APPL IS |
| | 1.5 KW MIN, PLEASE ALSO SEE DINING RM |
| | RQ'D RECEPTS. |
| | |
| | 3)NOTE: PLEASE SEE 5KW SHOWN ON 1P20A |
| | BRKR FOR GOLF CART CHARGER. |
| | PLEASE SEE 3KW ON 1P20A BATH GFI |
| | CIRCUIT. |
| | PLEASE ADJUST. |
| | LOADS EXCEED RATINGS OF CIRCUITS. |
| | 240.4 ETC. |
| | |
| | 4)NOTE:PLEASE SEE MAIN BRKR PANEL "B", |
| | IS SHOWN AS 8-16 CIRCUIT PANEL YET, |
| | PANEL "B" IS SHOWN ASA 42 CIRCUIT |
| | PANEL ON PANEL SCHEDULE. |
| | |
| | 5)NOTE: PLEASE SHOW PANEL "C" ON PLANS. |
| | COULD NOT LOCATE THIS ON PLANS. |
| | |
| | |
| | 6 )NOTE: PLEASE SEE 220.3B4. |
| | PLEASE SHOW ALL RECESSED LTS BASED ON |
| | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT |
| | BE FIGURED IN W/ 3W/PER SQ FT. |
| | PLEASE PROVIDE FIXTURE INFORMATION ON |
| | LEGEND. |
| | |
| | |
| | PLEASE SUBMIT THE ABOVE INFORMATION FOR |
| | REVIEW. IF THERE ARE ANY QUESTIONS, |
| | PLEASE DO NOT HESITATE TO CALL. |
| | |
| | DEWEY PALMER |
| | ELECTRICAL PLAN REVIEW |
| | CITY OF WEST PALM BEACH |
| | CONSTUCTION SERVICES DEPT. |
| | 561-805-6717 |
| | [email protected] |