| 2004-06-02 00:00:00 | BUILDING PLAN REVIEW: FAILED |
| | |
| | 1. BEFORE A PERMIT TO CONSTRUCT MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALMBEACH COUNTY.THE ACTUAL PERMIT |
| | PLANS |
| | MUST BE STAMPED BY THAT OFFICE, AND A |
| | COPY OF THE PAID RECEIPT ATTACHED TO |
| | THE PERMIT APPLICATION.PLEASE CALL |
| | (561) 233-5025 FOR MORE INFORMATION. |
| | |
| | 2. SUBMIT THE ENGINEERING FOR THE BUTT |
| | GLASS ASSEMBLY INCLUDING MFGRS. SPECS |
| | ON SILICONE GEL BEING USED.THE |
| | ENGINEER MUST INSPECT THE UNIT WHEN |
| | INSTALLED AND PROVIDE A SIGNED & SEALED |
| | LETTER STATING IT IS INSTALLED PER HIS |
| | SPECIFICATIONS. PRODUCT APPROVALS ARE |
| | ALSO REQUIRED. |
| | |
| | 3. HIGHLIGHT THE MIAMI/DADE PRODUCT |
| | APPROVALS FOR THE FIXED WINDOWS SHOWING |
| | SIZE AND SHAPE BEING INSTALLED. |
| | |
| | 4. THE DESIGN PRESSURES OF THE GARAGE |
| | DOORS AS STATED ON THE PLANS DO NOT |
| | MATCH THE PRODUCT APPROVALS.PLEASE |
| | CORRECT. |
| | |
| | 5. SEE NOTES FROM ELECTRIC REGARDING |
| | THE ARCHITECT TITLE BLOCK AND SIGNATURE |
| | REQUIREMENTS PER FS 481.221 |
| | |
| | 6. HIGHLIGHT THE TYPE OF CEMENT TILE |
| | BEING INSTALLED ON THE PRODUCT |
| | APPROVALS. |
| | |
| | ANY QUESTIONS PLEASE CALL: |
| | LEA SMITH, BUILDING PLANS EXAMINER |
| | 805-6713 |