2004-06-15 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04050700
 ADD: 600 NORTHPOINT PKWY
 ( PHASE VIII/ ACCESSIBLE
 GUESTROOMS)
 CONT: AMERICAN BUILDING INTERIORS
 TEL: (239)542-5717
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1ST REVIEW
 ACTION: DENIED
  
 1) DOUBLE/ DOUBLE: 11-9.2.2(6)(A)
 WHERE PROVIDED AS PART OF AN ACCESSIBLE
 UNIT, SLEEPING ROOM, OR SUITE THE FOLLOW
 ING SPACES SHALL BE ACCESSIBLE AND SHALL
 BE ON AN ACCESSIBLE ROUTE.
 (A) LIVING AREA. A PERSON IN A WHEEL
 CHAIR CAN'T GET BY THE DESK AND CHAIR,
 ONLY 2'-3".
  
 2)704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
  
 3) TABLE 803.3 MINIMUM INTERIOR FINISH
 CLASSIFICATION; PROVIDE INFORMATION
 BASED ON INTERIOR FINISH REQUIREMENTS
 BASED ON OCCUPANCY
  
 4) ACCESSIBLE KING SUITE, THE DOOR THAT
 LEADS INTO THE SUITE IF IN THE ROOM
 ALREADY HOW ARE YOU GOING TO GET THE
 WHEELCHAIR AROUND THE DOOR LEADING INTO
 THE SECOND ROOM? DOOR IS NOT INDICATED
 AS HAVING 180 DEGREE HINGES.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.