| Date |
Text |
| 2004-06-03 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 04050601 |
| | ADD: 622 N FLAGLER DR# 1204 |
| | CONT: LIVINGSTON |
| | TEL: (561)371-9685 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1)412.6.2 ALL ROOMS AND ENCLOSURES SHALL |
| | HAVE AT LEAST ONE EXIT ACCESSIBLE WITH- |
| | OUT TRAVEL THROUGH THE ELEVATOR LOBBY. |
| | |
| | 2)FL BLD CODE 104.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED, |
| | PLANS DO NOT INDICATE HOW THE VARIOUS |
| | SOFFITS ARE TO BE BUILT, MATERIALS, |
| | SPACING OR ATTACHMENT TO STRUCTURE |
| | ABOVE. |
| | |
| | 3) PLANS ALSO INDICATE A NEW PREMANUFACT |
| | URED DOME. ADDITIONAL INFO REQUIRED. |
| | FOAM PLASTIC TRIM 803.4 |
| | FOAM PLASTICS SHALL NOT BE USED AS INTER |
| | IOR FINISHES. |
| | EXCEPTION: FOAM PLASTIC TRIM, DEFINED AS |
| | PICTURE MOLDS, CHAIR RAIL, BASEBOARDS, |
| | HANDRAILS CEILING BEAMS, DOOR TRIM AND |
| | WINDOW TRIM, OR CROWN MOLDING SHALL BE |
| | PERMITTED PROVIDED: |
| | 1) THE MINIMUM DENSITY IS 20 LB/CU FT. |
| | 2) THE MAXIMUM THICKNESS IS 1/2" AND |
| | THE MAXIMUM WIDTH IS 4". |
| | 3) THE TRIM CONSTITUTES NO MORE THAN |
| | 10% OF THE AREA OF WALL OR CEILING. |
| | 4) THE FLAMESPREAD RATING DOES NOT |
| | EXCEED 75 WHEN TESTED PER ASTM E 84. THE |
| | SMOKE DEVELOPMENT RATING IS NOT LIMITED. |
| | |
| | 4)704.2.1.4 CORRIDOR PARTITIONS, SMOKE |
| | STOP PARTITIONS, HORIZONTAL EXIT PART- |
| | ITIONS, EXIT ENCLOSURES, AND FIRE |
| | RATED WALLS REQUIRED TO HAVE PROTECTED |
| | OPENINGS SHALL BE EFFECTIVELY AND |
| | PERMANETLY IDENTIFIED WITH SIGNS OR |
| | STENCILING IN A MANNER ACCEPTABLE TO THE |
| | AUTHORITY HAVING JURISDICTION. SUCH IDEN |
| | TIFICATION SHALL BE ABOVE ANY DECORATIVE |
| | CEILING CEILING AND IN CONCEALED SPACES. |
| | SUGGESTED WORDING" FIRE & SMOKE BARRIER |
| | PROTECT ALL OPENINGS". |
| | |
| | 5) 609.2.1 PARTITIONS OF TYPE I OR II |
| | BUILDINGS SHALL BE CONSTRUCTED OF NON- |
| | COMBUSTIBLE MATERIAL. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |