| 2007-01-05 08:44:09 | BUILDING PLAN REVIEW |
| | PERMIT: 04042022 |
| | ADD: 444 W RAILROAD AVE |
| | CONT: PBM DEVELOPMENT |
| | TEL: (954)868-5944 |
| | |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVISIONREVIEW |
| | ACTION: DENIED |
| | |
| | 1) PBM DEVELOPMENT IS ACTING AS A ARCHITECTURAL FIRM, |
| | EITHER PBM DEVELOPMENT NEEDS TO AQUIRE A CERTIFICATE |
| | OF AUTHORIZATION OR REMOVE THEIR NAME FROM THE |
| | TITLEBLOCK |
| | AND USE THE LICENSED ARCHITECT DOMINICK SCARFO INTHE |
| | TITLE |
| | BLOCK AS AN INDIVDUAL. |
| | |
| | 481.219 F.S.CERTIFICATE OF |
| | AUTHORIZATION.THE TITLE BLOCK FOR ANY |
| | SHEET BEARING THE NAME OF AN ARCHITECT |
| | PRACTICING UNDER A FICTITIOUS NAME, A |
| | CORPORATION, OR A PARTNERSHIP, OFFERING ARCHITECTURAL |
| | SERVICES, SHALL |
| | INCLUDE THE CERTIFICATE OF AUTHORIZATION |
| | NUMBER.ADD THE NUMBER TO EACH SHEET. |
| | THIS MAY BE ADDED BY HAND. |
| | |
| | 2) THE SECOND ISSUE WITH THIS SERIES OF REVISIONS IS : |
| | A.31.03 THE THIRD FLOOR CORRIDOR, A.31.04 FOURTH FLOOR, |
| | THE NEW CORRIDOR |
| | WALLS ANDDOORS DO NOT INDICATE ANY RATINGS. THE |
| | NARRATIVE AND THE ARCHITECTURAL NOTES ON SHEET A.00.00 |
| | HAVE A PHRASE " CORRIDOR RATED" DRYWALL PARTITIONS. |
| | THERE IS A DIFFERENCE IN CORRIDOR RATINGS UNDER THE |
| | 2001FBC AND 2004 FBC. THE ISSUED PERMIT SET OF PLANS |
| | UNDER THE 2001 FBC INDICATE WALL TAG (102)HR FIRE |
| | RATED CORRIDORS AND |
| | 20 MINUTE DOORS. THE DOORSIN THE NEWLY ADDED |
| | CORRIDORS DO NOT HAVE ANY |
| | IDENTIFICATION MARKERS EITHER. |
| | |
| | PLEASE PROVIDE WALL AND DOOR MARKER INDICATING THEIR |
| | FIRE RATINGS. |
| | |
| | 3) A.41.03 REVISION# 7 THERE IS NO CEILING HEIGHT |
| | INDICATORS |
| | ALTHOUGH NOTE# 4AS NOTED.ADDITIONAL INFORMATION |
| | REQUIRED. 106.1.2. |
| | |
| | 4A) A.41.04 REVISION# 1 NEW CEILING DESIGN IN LOBBY, NO |
| | |
| | INFORMATION AS TO HEIGHT OR TYPE OF MATERIALS TO BE |
| | USED. |
| | ADDITIONAL INFORMATION REQUIRED. 106.1.2. |
| | |
| | 4B) A.41.04 REVISION# 2THERE IS NO CEILING HEIGHT |
| | INDICATORS |
| | ALTHOUGH NOTE# 4AS NOTED.ADDITIONAL INFORMATION |
| | REQUIRED. 106.1.2. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER C. B. O. |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |
| | |