| Plan Review Notes For Permit 04041978 |
| Permit Number |
04041978 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2004-05-17 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHT. A-7 SANITARY RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN. BATH #1 NOT | | | ON FLOOR PLAN BUT SHOWN ON RISER DIAGRAM | | | - MASTER BATH SHALL BE LOCATED TO THE | | | LEFT OF THE BLDG DRAIN AFTER IT ENTERS | | | THE BLDG. RISER SHOWS IT TO THE LEFT | | | THEN TURNING BACK TO FRONT OF HOUSE. - | | | POWDER ROOM SHALL CONNECT PRIOR TO MAST- | | | ER BATH. - CLEANOUT REQUIRED ON WASH | | | MACHINE STACK 4' ABOVE FLOOR. - LAV IN | | | 2ND FLOOR BATH SHALL CONNECT ABOVE THE | | | FLOOR. SECTIONS 104.2.1 - 708.10 | | | 2) ALL DRAWINGS SHALL BEAR THE NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR | | | THE DESIGN. SECTION 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|