Notes
Date Text
2004-05-17 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHT. A-7 SANITARY RISER DIAGRAM DOES
 NOT REFLECT THE FLOOR PLAN. BATH #1 NOT
 ON FLOOR PLAN BUT SHOWN ON RISER DIAGRAM
 - MASTER BATH SHALL BE LOCATED TO THE
 LEFT OF THE BLDG DRAIN AFTER IT ENTERS
 THE BLDG. RISER SHOWS IT TO THE LEFT
 THEN TURNING BACK TO FRONT OF HOUSE. -
 POWDER ROOM SHALL CONNECT PRIOR TO MAST-
 ER BATH. - CLEANOUT REQUIRED ON WASH
 MACHINE STACK 4' ABOVE FLOOR. - LAV IN
 2ND FLOOR BATH SHALL CONNECT ABOVE THE
 FLOOR. SECTIONS 104.2.1 - 708.10
 2) ALL DRAWINGS SHALL BEAR THE NAME AND
 SIGNATURE OF THE PERSON RESPONSIBLE FOR
 THE DESIGN. SECTION 104.2.1
  