Plan Review Notes
Plan Review Notes For Permit 04041916
Permit Number 04041916
Review Stop E
Sequence Number 1
Notes
Date Text
2004-05-10 00:00:00********** UNSAT ****************
  
 1)NOTE: PLEASE SEE POOL PANEL NOT SHOWN
 ON RISER DAIGRAM.
  
 2)NOTE: PLEASE SEE PANEL SCHEDULES AND
 RISER SHOWS PANELS AS MLO.
 PLEASE ADJUST.
  
 3)NOTE: PLEASE SEE MISSING RECEPTS PER
 210.52, 210.52C1
 BR# 4 KIT COUNTER.
  
 4)NOTE: PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]