2004-05-10 00:00:00********* UNSAT ***************
  
 1)NOTE: PLEASE SEE MISSING LICENSE #'S
 REQUIRED TO BE PRINTED ON TITLE BLOCK.
 FS 481.219/ FAC 61G1-16.004
  
 2)NOTE: PLEASE SEE MISSING POOL PANEL
 FROM RISER DIAGRAM.
  
 3)NOTE: PLEASE SEE BOTH PANEL SCHEDULES
 AND RISER DIAGRAM SHOW PANELS AS MLO?
 PLEASE ADJUST TO INDICATE MCB IN BOTH
 LOCATIONS.
  
 4)NOTE: PLEASE SEE WHAT APPEARS TO BE
 A FLR RECEPT SHOWN IN THE PATH OF EGRESS
 TO OUTSIDE FROM LIVING RM?
 PLEASE ALSO SEE WHAT APPEARS TO BE BACK
 PORCH IS SHOWN AS LIVING RM?
  
 5)NOTE: PLEASE SEE 210.52C1 FOR MISSING
 RECEPT ON KIT COUNTER.
  
 6 )NOTE: PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND.
  
 7)NOTE: PLEASE SEE MISSING GFI RECEPT
 IN CABANA BATH. 210.52D
  
 8)NOTE: PLEASE SEE GFI SHOWN IN GARAGE
 APPEARS TO BE A DEDICATED RECEPT FOR
 GOLF CHARGER WHICH IS LISTED ON PANEL
 SCHEDULE.
 PLEASE SEE GFI REQ'D FOR GEN PURPOSE
 PER 210.52G/210.8
  
 9)NOTE: PLEASE SHOW SERVICE ON PLANS,
 PLEASE INDICATE LOCATION OF PANELS/METER
  
 PLEASE SEE ONE SET OF PLANS HAS BEEN
 HIGHLIGHTED FOR SOME OF THE ABOVE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW