| Plan Review Notes For Permit 04040778 |
| Permit Number |
04040778 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2004-05-13 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 040407781) | | | ADD: 201 S NARCISSUS AV | | | CONT: MC LAREN CONST | | | TEL: (561)686-6500 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | 803.4 FOAM PLASTICS. FOAM PLASTICS SHALL | | | NOT BE USED AS INTERIOR FINISH. | | | EXCEPTION: | | | A) THE MINIMUM DENSITY IS 20LB/CU FT . | | | B) THE MAXIMUM THICKNESS OF THE TRIM IS | | | 1/2" AND THE MAXIMUM WIDTH IS 4". | | | C) THE TRIM CONSTITUTES NO MORE THAN | | | 10% OF THE AREA OF ANY WALL OR | | | CEILING. | | | D) THE FLAMESPREAD RATING DOES NOT EX- | | | CEED 75 WHEN TESTED PER ASTM E 84. | | | | | | 2) MARBLE FIREPLACE: | | | PROVIDE ADDITIONAL INFORMATION: | | | IS THIS A ACTIVE FIREPLACE WITH A MARBLE | | | SURROUND? | | | FALSE FIREPLACES, 2807, FALSE FIREPLACES | | | MAY BE USED IN CONNECTION WITH LISTED | | | GAS OR ELECTRIC HEATERS, PROVIDED SUCH | | | FIREPLACES ARE CONSTRUCTED OF NONCOMBUST | | | IBLE MATERIALS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|