| Plan Review Notes For Permit 04040453 |
| Permit Number |
04040453 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2004-04-27 00:00:00 | DENIED | | | ITEMS NOT CORRECTED FROM FIRST REVIEW | | | | | | 1.SHOW FASTENING DETAIL FOR 2 X 10. | | | SHOW SIZE AND LENGTH OF FASTENERS. | | | | | | 2.ONLY ONE COPY OF ROOFING PRODUCT | | | APPROVAL SUBMITTED.SUBMIT 2 COPIES. | | | I THOUGHT THE ROOF WAS GOING TO BE TILE? | | | | | | 3.DRAWING NOT TO SCALE. WEST PALM | | | BEACH AMMENDMENT TO THE FBC 104.2.1.3 | | | QUALITY OF BUILDING PLANS | | | | | | 4.SHOW ROOF FRAMING DEMENTIONS, | | | "TYPE OF LUMBER USED" AND SHOW ALL | | | STRAPING AND TYPE OF STRAPS USED AND | | | REQUIRED.MANY STRAPS ARE MISSING FROM | | | PLAN. | | | | | | NOTE:ARE YOU CHANGING THE FOOTING | | | SIZE?ARE YOU CHANGING THE METHOD OF | | | ATTACHMENT TO THE FOOTING?PLEASE | | | VERIFY AND SHOW DETAIL INCLUDING STRAPS | | | USED AND METHOD OF ATTACHMENT. | | | | | | WHEN SUBMITTING PLANS SUBMIT OLD COPIES | | | WITH NEW PLANS.SPECIFY AREAS WHERE | | | CHANGES TO PLANS HAVE BEEN MADE. | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|