Plan Review Notes
Plan Review Notes For Permit 04031591
Permit Number 04031591
Review Stop M
Sequence Number 9
Notes
Date Text
2005-10-17 00:00:00PLEASE NOTE DOORS SUBMITTED FOR THE A/C
 CLOSET ARE ACCEPTABLE BUT ARE ONLY
 REQUIRED TO COMPLY WITH 2001 FBC CHAPTER
 2:
  
 NONCOMBUSTIBLE BUILDING MATERIAL. A
 MATERIAL WHICH MEETS EITHER OF THE
 FOLLOWING REQUIREMENTS:
  
 1. MATERIALS WHICH PASS THE TEST
 PROCEDURE SET FORTH IN ASTM E 136.
  
 2. MATERIALS HAVING A STRUCTURAL BASE
 OF NONCOMBUSTIBLE MATERIALS AS
 DEFINED IN 1, WITH A SURFACING NOT
 MORE THAN 1/8 INCH (3.17 MM) THICK
 WHICH HAS A FLAMESPREAD RATING NOT
 GREATER THAN 50 WHEN TESTED IN
 ACCORDANCE WITH ASTM E 84.
  
 THE TERM NONCOMBUSTIBLE DOES NOT APPLY
 TO THE FLAMESPREAD CHARACTERISTICS
 OF INTERIOR FINISH OR TRIM MATERIALS. A
 MATERIAL SHALL NOT BE CLASSED AS
 NONCOMBUSTIBLE WHICH IS SUBJECT TO
 INCREASE IN COMBUSTIBILITY OR
 FLAMESPREAD RATING BEYOND THE LIMITS
 HEREIN ESTABLISHED THROUGH THE
 EFFECTS OF AGE, MOISTURE OR OTHER
 ATMOSPHERIC CONDITIONS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.