| 2007-09-30 14:57:53 | BUILDING PLAN REVIEW |
| | *******DENIED******* |
| | ROBERT BROWN(561) 805 6652 |
| | E-MAIL: [email protected] |
| | |
| | REVISION SUBMITTED 7/27/07 FOR PARKING SPACE LAYOUT |
| | |
| | FBC = FLORIDA BUILDING CODE 2001 |
| | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) |
| | F.S.= FLORIDA (STATE) STATUTE |
| | |
| | 1) FAIR HOUSING ACT REQUIREMENT 2 AND FBC |
| | 11-4.1.2(5)(A)-NUMBER OF ACCESSIBLE PARKING SPACES. |
| | THE SUBMITTED REVISED PLANS SHOW A PROPOSAL TO REDUCE |
| | THE NUMBER OF ACCESSIBLE PARKING SPACES BUT A REVISED |
| | SHEET A0-2 (REVISION # 38 IS THE LATEST ON FILE) HAS |
| | NOT BEEN SUBMITTED WITH A REVISED PARKING SPACE TABLE. |
| | TO PROCEED WITH THIS REVISION THE PARKING TABLE MUST BE |
| | REVISED TO DEMONSTRATE COMPLIANCE WITH THE FAIR HOUSING |
| | ACT REQUIREMENT FOR 2% OF THE PARKING SPACES TO BE |
| | ACCESSIBLE, AND FBC 11-4.1.2(5)(A) REQUIREMENT FOR |
| | COMMERCIAL SPACE (INCLUDING LIVE/WORK LOFTS) TO HAVE 1 |
| | ACCESSIBLE SPACE FOR EVERY 25 PARKING SPACES. |
| | |
| | 2)FBC 3203-THE SUBMITTED REVISED PLANS SHOW A |
| | NUMBER OF REVISIONS THAT HAVE NOT BEEN SUBMITTED |
| | PREVIOUSLY, INCLUDING LOFT DOORS SWINGING ACROSS THE |
| | NORTH PROPERTY LINE INTO THEPUBLIC RIGHT OF WAY.THE |
| | LATEST REVISION OF THE GROUND LEVEL PLANS ON FILE SHOW |
| | INSWING DOORS.DOORS SHALL NOT SWING OVER PUBLIC |
| | PROPERTY. |