| 2004-04-09 00:00:00 | DENIED |
| | 1.BEFORE A PERMIT TO CONSTRUCT, MAY |
| | BE ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 2. THE NOTICE OF COMMENCEMENT SHALL BE |
| | RECORDED AT PALM BEACH COUNTY |
| | COURTHOUSEAND A COPY SUBMITTED TO THIS |
| | OFFICE |
| | BEFORE A PERMIT CAN BE ISSUED.BLANK |
| | FORMS ARE AVAILABLE FROM THIS OFFICE. |
| | |
| | 3.SHOW GRADE AND HEIGHT OF FINISH |
| | FLOOR. WPB AMMENDMENTS HABITABLE AREAS |
| | SHALL BE A MINIMUM OF 4" ABOVE THE |
| | FINISH GRADE. |
| | |
| | 4.SUBMIT 2 COMPLETE COPIES OF PRODUCT |
| | APPROVALS. |
| | |
| | 5.IMPACT PROTECTION REQUIRED ON NEW |
| | WINDOWS.SUBMIT PRODUCT APPROVALS FOR |
| | SHUTTERS. |
| | |
| | 6. EXISTING WINDOW THAT IS CLOSED OFF. |
| | IS IT A BEDROOM?IF SO EGRESS OPTIONS |
| | NEED TO BE ADDRSSED. |
| | |
| | 7.SPECIFY WALL AND ROOF SHEATHING |
| | NAILING AND FASTENER SIZE. |
| | |
| | 8. PERMIT VALUATION TOO LOW. BASED UPON |
| | SBCCI BUILDING VALUATION DATA THE PERMIT |
| | VALUE HAS BEEN CHANGED TO $35,555. |
| | ADDITIONAL PERMIT FEES ARE DUE. |
| | |
| | 9.SQUARE FOOTAGE OF ROOM ADDITION IS |
| | 462 CORRECTED FROM 440SQ. FT. |
| | |
| | 10.GLASS IN BATHROOM OVER TUB SHALL |
| | COMPLY WITH FBC 2505.2.1 |
| | |
| | 11.SHOW DETAIL HOW NEW FOOTING IS |
| | GOING TO BE SECURED TO EXISTING SLAB. |
| | |
| | 12.SHOW ROOF FRAMING DETAIL, TYPE OF |
| | LUMBER, SPACING, BLOCKING. SUBMIT DETAIL |
| | |
| | 13.SUBMIT A WALL FRAMING DETAIL FOR |
| | NEW INTERIOR AND EXTERIOR WALLS.SHOW |
| | TYPE AND SIZE OF LUMBER TYPE AND SIZE |
| | OFSTRAPS USED.SILL PLATE FASTENING. |
| | SHOW WINDOW/DOOR BUCK DETAIL COMPLYING |
| | WITH FBC 1707.4.4.2. |
| | |
| | 14.ROOFING PRODUCT APPROVAALS MISSING. |
| | |
| | 15.WINDOW MULLION PRODUCT APPROVALS |
| | MISSING. |
| | |
| | ANY QUESTIONS CALL ME. |
| | |
| | ART LANGE |
| | BUILDING PLANS EXAMINER |
| | 805-6672 |