| 2004-04-28 00:00:00 | DENIED |
| | |
| | 1) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 2) THE PLAN REVIEW NUMBER ON THE IMPACT |
| | FEE RECEIPT DOES NOT MATCH THE ONE THAT |
| | IS STAMPED ON THE PLANS. SUBMIT THE |
| | CORRECT RECEIPT. |
| | |
| | 3) SPECIFY THE DESIGN PRESSURES FOR THE |
| | FRONT DOOR ON THE PLANS. |
| | |
| | 4) THERE ARE TWO DIFFERENT SETS OF |
| | DESIGN PRESSURES LISTED FOR EACH OF THE |
| | TWO WINDOW OPENINGS ON EACH SIDE OF THE |
| | FRONT DOOR. THESE SHOULD ONLY HAVE ONE |
| | SET OF PRESSURES FOR EACH OPENING. |
| | PLEASE CORRECT. |
| | |
| | 5) THERE IS A SET OF PRESSURES LISTED |
| | BELOW THE FRONT ELEVATION ON SHEET 1. |
| | PLEASE CORRECT. |
| | |
| | 6) SPECIFY ON THE PLANS THAT THE WELDED |
| | WIRE MESH IN THE SLAB IS TO BE SUPPORTED |
| | ON APPROVED SUPPORTS AT NO MORE THAN 3' |
| | O.C. PER FBC 1909.3. |
| | |
| | 7) REVISE THE HIGH RIB LATH NOTE ON |
| | SHEET 3 TO REQUIRE FASTENING AT EVERY |
| | RIB (4"OC) AS REQUIRED BY ASTM C 1063. |
| | |
| | 8) SPECIFY ON THE PLANS THAT THE DOOR |
| | FROM THE GARAGE TO THE CONDITIONED SPACE |
| | IS REQUIRED TO BE SOLID CORE OR |
| | INSULATED AS REQUIRED BY FBC 13-603. |
| | |
| | 9) THERE IS A LINE THROUGH THE ROOF |
| | NOTES AND CONNECTOR SCHEDULE ON SHEET 5. |
| | ARE THESE TABLES STRICKEN FROM THE PLANS |
| | PLEASE CLARIFY AND CORRECT. |
| | |
| | 10) SUBMIT STATE PRODUCT APPROVAL FOR |
| | THE SINGLE OUTSWING ENTRY DOOR WITH |
| | SIDELITES. |
| | |
| | 11) SUBMIT STATE PRODUCT APPROVAL WITH |
| | APPROVED STATUS FOR THE COLLIER GARAGE |
| | DOOR. |
| | |