2004-03-23 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHTS P-3 & P-5 (SANT. ISOMETRIC), HUB
 DRAIN SHALL CONNECT TO VENTED 4" COMBIN-
 ATION WASTE AND VENT LINE NOT FLOOR
 DRAIN LINE. SECTION 912.2.2
 2) FILTERS SHALL MEET REQUIREMENT OF
 NSF-42 DRINKING WATER TREATMENT UNITS -
 AESTHETIC EFFECTS, OR WATER QUALITY
 ASSOCIATION STANDARD S-200, HOUSEHOLD
 & COMMERCIAL WATER FILTERS (IN LINE). -
 MANUFACTURE SPECIFICATION SHEETS REQ'D.
  