| Notes |
| Date |
Text |
| 2004-03-29 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SANITARY RISER DIAGRAM DOES NOT MEET | | | CODE REQUIREMENTS NOR DOES IT REFLECT | | | THE FLOOR PLAN. | | | A) LAV IN BATHROOM NOT VENTED AND IS AN | | | "S" TRAP. SECTIONS 901.2.1 & 1002.3 | | | B) HORIZONTAL DRY VENT NOT APPROVED. | | | SECTION 905.3 | | | C) TUB TO BE UPSTREAM OF W/C AND ALL | | | FIXTURES ON SAME WALL IN 2ND BATH. | | | SECTION 104.2.1 | | | D) W/C AND SHOWER ON WRONG WALL. | | | E) SEE ATTACHED SHEET FOR RISER DIAGRAM | | | THAT MEETS CODE AND REFLECTS THE FLOOR | | | PLAN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|