Plan Review Notes
Plan Review Notes For Permit 04021372
Permit Number 04021372
Review Stop B
Sequence Number 2
Notes
Date Text
2004-07-23 00:00:00DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) NO REDLINE CHANGES INITIALED & DATED
 BY THE DESIGNER OF RECORD ARE ALLOWED ON
 MASTER PLAN. REVISE THE ORIGINAL
 DRAWINGS.
  
 3) CITY AMENDMENTS TO FBC TABLE 2306.1
 REQUIRES THE ROOF SHEATHING TO BE NAILED
 WITH 8D RING SHANK NAILS IN ZONE THREE
 FOR BUILDINGS WITH A MEAN ROOF HEIGHT
 OF 25'- 35'. REVISE SCHEDULE ON S4.
  
 4) PROVIDE A SCHEDULE FOR THE CASTCRETE
 LINTELS THAT WILL BE USED ON THE PLANS.
 SPECIFY THE ALLOWABLE SAFE LOADS IN THE
 SCHEDULE.
  
 5) PROVDE STRUCTURAL DETAILS FOR THE
 GABLE END ROOF FRAMING AND OVERHANG.
 THE PLANS AND TRUSS LAYOUT ARE NOT CLEAR
 IN THIS AREA.
  
 6) SPECIFY THE GRAVITY LOAD CAPACITY FOR
 THE CCO SIMPSON COLUMN CAP ON THE PLANS.
  
 7) SPECIFY THE FASTENERS AND EMBED DEPTH
 ON THE STEEL COLUMN BASE DETAIL ON S5.
 CLARIFY THE NOTE THAT STATES WHERE
 NORMAL EMBEDMENT IS NOT POSSIBLE.
 PROVIDE AN ALTERNATE INSTALLATION DETAIL
 SHOWING EACH OPTION.
  
 8) SPECIFY THE TRUSS CONNECTORS FOR THE
 GR03 ROOF GIRDERS, WHICH ARE SHOWN ON
 THE TRUSS LAYOUT PARALLEL TO ONE HOUR
 TENANT SEPARATION WALL.
  
 9) REVISE CONNECTORS SPECIFIED FOR THE
 THREE PLY GIRDERS (GR01) AND TWO PLY
 GIRDERS (GR02,GR04,GR05) FROM THE
 SIMPSON MGT (MARK D) WHICH IS FOR A ONE
 PLY TRUSS TO AN APPROPRIATE CONNECTOR.
  
 10) REVISE THE UPLIFT VALUE OF THE HETAL
 20 CONNECTOR TO THE VALUE THAT DOES NOT
 INCLUDE A ONE-THIRD INCREASE IN THE
 STEEL CALCULATIONS (1810#). SEE
 FBC 1609.4.3. AND 2004 SIMPSON CATALOG.
  
 11) SUBMIT COVER SHEETS FOR STATE
 PRODUCT APPROVAL WITH FL NUMBERS FOR ALL
 PRODUCTS REQUIRED BY FAC RULE 9B-72.
 MAKE COPIES FOR ALL THREE SETS OF PLANS.
  
 12) PRODUCT APPROVAL THAT WAS SUBMITTED
 FOR THE ENTRY DOOR IS FOR A NON-IMPACT
 RATED DOOR AND WILL REQUIRE IMPACT
 PROTECTION.
  
 13) SUBMIT THE MANUFACTURER'S SPECS. AND
 LISTING INFO. FOR THE ONE HOUR FIRE
 RATED GLASS BLOCK.
  
 14) THE PRODUCT APPROVALS SUBMITTED FOR
 THE OVERHEAD GARAGE DOORS DO NOT MEET
 THE REQUIRED DESIGN PRESSURES LISTED IN
 THE SCHEDULE ON THE PLANS. SUBMIT INFO.
 FOR GARAGE DOORS WITH ADEQUATE DESIGN
 PRESSURES.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714