Plan Review Notes
Plan Review Notes For Permit 04021355
Permit Number 04021355
Review Stop P
Sequence Number 1
Notes
Date Text
2004-03-15 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FHA-98 DESIGN MANUAL
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 A) COMMENTS FROM PREVIOUS REVIEW NOT
 ADDRESSED. COMMENT NUMBER TO STAY THE
 SAME AS FIRST REVIEW TO AVOID CONFUSION.
 1) INDICATE SPECIFICATION "A" OR "B" AS
 REQUIRED IN FHA DESIGN MANUAL REQUIRE-
 MENT 7B PAGES 7.34 & 7.35. - RESPONSE
 NOTED, BUT SPECIFICATION NOT FOUND ON
 SHEET A-3 AS INDICATED.
 2) SHOW LAV HEIGHT PER FHA DESIGN MANUAL
 PAGE 9512 SECTION "V". RESPONSE NOTED,
 BUT 36" IS INCORRECT. 34" IS MAX. HEIGHT
 3) SHT A-15 GRAB BAR BLOCKING DETAILS
 SHALL REFLECT BACKING IN CHAPTER 6 OF
 THE FHA DESIGN MANUAL. - RESPONSE NOTED,
 BUT SHEET A-19 DETAIL DOES NOT REFLECT
 THE DESIGN MANUAL REQUIREMENTS.
 4) A SANITARY AND A WATER RISER DIAGRAM
 ARE REQURED PER SECTION 104.3.1.1. - RE-
 SPONSE NOTED, BUT NO WATER RISER DIAGRAM
 HAS BEEN SUBMITTED,
 8) PLANS HAVE STAMPED WITH A SIGNATURE
 STAMP. A WET SIGNATURE IS REQUIRED ON
 THE SEAL. NO CERTIFICATE OF AUTHORIZAT-
 ION IS SHOWN ON THE TITLE BLOCK.
 A PROFESSIONAL ENGINEER SHALL SIGN HIS
 NAME AND AFFIX HIS SEAL TO ALL PLANS,
 SPECIFICATIONS, REPORTS AND FINAL BID
 DOCUMENTS PROVIDED TO THE OWNER OR THE
 OWNER'S REPRESENTATIVE, OR OTHER DOCU-
 MENTS PREPARED OR ISSUED BY SAID REGIS-
 TRANT AND BEING FILED FOR PUBLIC RECORD.
 THE DATE THAT THE SIGNATURE AND SEAL IS
 AFFIXED AS PROVIDED HEREIN SHALL BE EN-
 TERED ON SAID PLANS, SPECIFICATIONS, RE-
 PORTS, OR OTHER DOCUMENTS IMMEDIATELY
 UNDER THE SIGNATURE OF THE PROFESSIONAL
 ENGINEER, FAC 61G15-23.002(1)
 FS 471.025
 EACH SHEET OF PLANS AND PRINTS WHICH
 MUST BE SEALED UNDER THE PROVISIONS OF
 CHAPTER 471 SHALL BE SEALED, SIGNED AND
 DATED BY THE PROFESSIONAL ENGINEER IN
 RESPONSIBLE CHARGE. FAC 61G15-23.002(2)
 FS 471.025
 ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025
 ****************NEW COMMENTS************
 1B) CLEAR FLOOR SPACE SHALL BE APPLIED
 OR SUPERIMPOSED OVER A PLAN DURING THE
 DESIGN PROCESS TO DETERMINE IF SPACE RE_
 QUIREMENTS ARE BEING MET. PAGE 7.43 OF
 THE DESIGN MANUAL.
  