2004-03-23 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04021355
 ADD: 1770MISSION COURT
 CONT: WCI COMMUNITIES
 TEL: (561)775-2120
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1ST PERMIT REVIEW
 PLAN REVIEW: 04010005
  
 ACTION: DENIED
  
 NOTE: A SIGNED & SEALED LETTER FROM THE
 ARCHITECT OF RECORD INDICATING THE PLANS
 SUBMITTED ARE OCCUPANCY TYPE: (R2).
 WITH THE PLANS STATING "TOWNHOUSE" AS
 PART OF THE NAME IT IS TO BE MADE CLEAR
 THAT ALL DOCUMENTS INCLUDING THE SOILS
 REPORTS SHOULD NOT STATE TOWNHOMES.
 FOR THESE UNITS TO BE SOLD AS CONDOMIN
 IUMS A RECORDED DECLARATION OF CONDOMIN-
 IUM SHALL BE REQUIRED BEFORE A CERTIFI-
 CATE OF OCCUPANCY WILL BE ISSUED.
  
 1) 105.3 CITY ADMINISTRATIVE CODE,
 RESIDENT INSPECTOR TO BE REQUIRED.
 CONTACT HAROLD PISKURA)@ 805-6711 FOR
 MORE INFORMATION AS TO THE REQUIREMENTS
 OF COMPLETED UNITS VS CONSTRUCTION AREAS
 REQUIRED STRUCTURAL INSPECTIONS AND
 PHASING.
  
 2)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 2ND REQUEST!!!!!!!!!!!!!!!!!
 A SITE PLAN INDICATING ALL SITE AMENIT-
 IES WITH DIMENSIONS BETWEEN BUILDINGS
 INDICATING THE ASSUMED PROPERTY LINE
 BETWEEN BUILDINGS, TO CALCULATE ALLOW-
 ABLE OPENING SIZES TABLE 600. UNABLE TO
 VARIFY COMPLIANCE WITH TABLE 600.
 " 2ND REQUEST". HIGHLIGHT WHICH BUILDING
 IS PERMITTED UNDER THIS PERMIT!
  
 3) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 WHERE THE BEARING CAPACITY OF THE SOIL I
 S NOT DEFINITEY KNOWN, OR IS IN QUESTION
 THE BUILDING OFFICIAL MAY REQUIRE EXPLOR
 ATIONS, TEST OR OTHER ADEQUATE PROOF AS
 TO THE PERMISSIBLE SAFE BEARING
 CAPACITY. REQUIRED TEST AND RECOMMENDA-
 TIONS SUBMITTED TO VERIFY BEARING CAPA-
 CITY SHALL BE CERTIFIED BY A GEOTECH-
 NICALREPORT FROM A DESIGN PROFESSIONAL P
 ROPERLY LICENSED IN THE STATE OF
 FLORIDA.
 PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
 2ND REQUEST, THE SOILS REPORT
 PROVIDED IS NOT THE ORIGINAL RAISED SEAL
 WITH ORIGINAL SIGNATURE.
  
 4)FBC 13-103.1.2 BEFORE A BUILDING
 PERMIT CAN BE ISSUED, THE SUBMITTED
 ENERGY CODE COMPLIANCE FORMS SHALL BE
 SIGNED BY THE BUILDING OWNER, THE
 OWNER'S ARCHETECT OR OTHER AUTHORIZED
 AGENT LEGALLY DESIGNATED BY THE OWNER.
  
 5) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
 2ND REQUEST!!!!!!!!
  
 6)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 7) FAIR HOUSING, 1. ACCESSIBLE ROUTE,
 INDICATE ON THE SITE PLAN, THE ACCESS-
 IBLE ROUTE TO ALL ELEMENTS, INCLUDING
 THE CLUBHOUSE,GAZEBOES,DUMPSTER, POOLS,
 PARKING AND PATH OF TRAVEL TO PUBLIC
 TRANSPORTATION.
  
 8) SHEET A-11 TYP 2 STORY DETAIL AT THE
 GARAGE MISSING FLOOR INSULATION OVER THE
 GARAGE. SEPERATION OF A/C VS NON.
 2ND REQUEST!!!!!!!!
  
 9) SHEET A-11 SECTION 3 & 4 INDICATE THE
 USE OF WIRE LATH ON THE SOFFIT, ADD INFO
 REQUIRED FOR INSTALLATION. I PROVIDED
 THE CODE ARTICLE FOR THE FASTENING TO
 HORIZONTAL FRAMING MEMBERS( 2504.2.2)
 FOR A REFRENCE ONLY PLEASE INDICATE
 FASTENING ON PLAN.
 104.2.1 W.P.B. ADMINISTRATIVE CODE
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN
 INFORMATION, IN THE FORM OF NOTES OR
 OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO
 CONFORMITY WITH THE TECHNICAL CODES.
 SUCH INFORMATION SHALL BE SPECIFIC
 AND THE TECHNICAL CODES "SHALL NOT BE
 CITED AS A WHOLE OR IN PART, NOR THE
 TERM "LEGAL" OR ITS RQUIVALENT BE USED
 AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION".
  
 10) FLORIDA STATEWIDE PRODUCT APPROVALS:
 A COVERSHEET FOR EACH PRODUCT APPROVAL
 SUBMITTED WAS PULLED FROM THE WEBSITE,
 COPY AND PROVIDE WITH EVERY PRODUCT
 APRROVAL SUBMITTED!!!!!!!!!!!!!!!!!!!
  
 11) PRODUCT APPROVALS SUBMITTED:
 AMARR GARAGE DOORS, SEE TABLE 1606.2B
 COMPONENTS & CLADDING WIND LOADS FOR A
 BUILDING WITH A MEAN ROOF HEIGHT OF <
 30' LOCATED IN EXPOSURE "B"
  
 BOTH THE 9' & 16' DOORS OK FOR 2STORY
 USE!!!!!!! LOW PRESSURE FOR 3 STORY USE
 WITH 1.09 MULTIPLIER 1606.2 D & E.
  
 12) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 2ND REQUEST FOR PRODUCT TESTING REPORTS
 FOR THE (G) STRUCTURAL COMPONENTS-
 WOOD CONNECTORS!!!!!!!!!!!!!!!
  
 13) 2ND REQUEST!!!!PROVIDE THE TRUSS
 ENGINEERING SHEETS WITH ALL LOADING
 CASES, VERTICAL, HORIZONTAL & GRAVITY
 LOADS. PLANS DO NOT INDICATE LOADING,
 ONLY THE ALLOWABLE VALUES FOR THE ANCHOR
  
 14) 2ND REQUEST: NOT ADDRESSED,
 1503.4.4 PROTECTION AGAINST DECAY &
 TERMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 15) 2ND REQUEST: GARAGE SWING DOOR,
 NOT LISTED ON DOOR SCHEDULE, A 3/4 HR
 RATING IS REQUIRED 411.2.6, 705.1.3.5,
 DOOR SHALL BE EQUIPPED WITH AN APPROVED
 CLOSER.
 A) THE FLORIDA BUILDING CODE UNDER
 THE ABOVE CODE ARTICLES DOES NOT INDI-
 CATE A "C" LABELED DOOR, IT IS A 45 MIN
 DOOR.
 B) PROVIDE THE CLOSER INFORMATION
 REQUIRED.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026