| Date |
Text |
| 2004-04-26 00:00:00 | BUILDING REVIEW CHECKLIST: |
| | 1-NOTICE OF COMMENCEMENT IS EXPIRED.NEED |
| | TO RENEW IT. |
| | 2-REVISE/CLARIFY SHEET A1: |
| | A)STORM SHUTTERS NOTE AND WINDOW GLAZING |
| | NOTE ARE CONFLICTING. CLARIFY IF USING |
| | STORM SHUTTERS OR MISSILE IMPACT GLASS |
| | B)NORTH ARROW IS POINTING TO THE WRONG |
| | ORIENTATION. SEE SURVEY AND REVISE |
| | AS REQUIRED. |
| | **NOTE: SAME THING ABOUT NORTH ARROW |
| | APPLIES TO SITE PLAN ON SHEET A5. |
| | 3-ACCORDING TO CLARIFICATION REGARDING |
| | MISSILE IMPACT PROTECTION AT GLAZED |
| | OPENINGS PROVIDE COMPLETE INFORMATION |
| | FOR EITHER OPTION. |
| | 4-PROVIDE COMPLETE SECTION DETAIL THRU |
| | ENTRY PORCH THAT MATCHES ROOF FRAMING |
| | PLAN. DETAILS ON SHEET A6 FOR KNEE |
| | WALL AND ENTRY PORCH SEC. DON'T MATCH. |
| | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. |
| | WHERE IS DETAIL E/6 TAKEN AT?. |
| | 5-CLEARLY SPECIFY ON PLANS IF ATTIC |
| | SPACE ABOVE GARAGE IS TO BE USED FOR |
| | STORAGE OR NOT. SEE TABLE 1604.1 FBC |
| | 2001. FOR REQUIRED DESIGN CRITERIA. |
| | 6-PROVIDE ATTIC ACCESS AT GUEST HOUSE. |
| | SEC. 2309.6 FBC 2001. |
| | 7-PROVIDE COMPLETE SECTION THRU BAY |
| | WINDOW. SEC. 104.2.1.2 CITY AMENDMENTS |
| | TO FBC 2001. |
| | 8-PLEASE PROVIDE ONLY THE DETAILS THAT |
| | APPLY TO THIS HOUSE TO EXPEDITE THE |
| | REVIEW PROCESS. |
| | 9-PRODUCT APPROVAL PACKAGE: A)FIXED |
| | WINDOWS NEED NOA AND DWGS THAT MATCH |
| | FLORIDA PRODUCT APPROVAL REPORT. |
| | B)PROVIDE PRODUCT APPROVAL FOR ENTRY |
| | DOORS WITH IMPACT GLAZING IF THIS |
| | OPTION IS TAKEN ON PLANS. |
| | C)PROVIDE COMPLETE PRODUCT APPROVAL FOR |
| | FRENCH DOORS WITH SIDELITES & TRANSOM |
| | ABOVE SINGLE ASSEMBLY AS SHOWN ON |
| | PLANS. CLEARLY SPECIFY ALL CONNECTIONS |
| | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. |
| | |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ AT 805-6712. |