| 2004-03-31 00:00:00 | BUILDING REVIEW CHECKLIST: |
| | 1-NEED RECORDED NOTICE OF COMMENCEMENT. |
| | 2-PROVIDE STRUCTURAL BUCK DETAIL @ ENTRY |
| | DOORS SHOWING SIZE OF BUCK REQUIRED TO |
| | CLOSE GAP ACCORDING TO MASONRY OPENING |
| | SHOWN. SEC. 104.2.1.2 CITY AMENDMENTS |
| | TO FBC 2001. |
| | 3-ENERGY CALCULATIONS: A)SINCE THIS IS |
| | NOT A WORST CASE SCENARIO CALCS, THEN |
| | ORIENTATION OF OPENINGS NEED TO MATCH |
| | PLANS. ALSO, OPENINGS TO MATCH PLANS. |
| | B)REVISE OVERHANG LENGTH AND HEIGHT TO |
| | MATCH FLOOR PLANS. |
| | 4-PROVIDE COMPLETE FLORIDA OR LOCAL |
| | PRODUCT APPROVAL FOR: |
| | A)ALL STRUCTURAL CONNECTORS. |
| | B)FRENCH DOORS WITH TRANSOM ABOVE SINGLE |
| | ASSEMBLY AS SHOWN ON PLANS. |
| | C)FIXED WINDOWS FOR BIG SIZES AS SHOWN |
| | ON PLANS. |
| | D)ROOF TILE |
| | E)WINDOW MULLIONS. |
| | F)GLASS BLOCK. 2 COPIES. |
| | |
| | 5-PROVIDE APROVAL AND SPECS FOR BBQ AS |
| | REQUIRED BY SEC. 2808 FBC 2001. |
| | 6-CLARIFY IF USING MISSILE IMPACT GLASS |
| | OR SHUTTERS. SEE NOTE ON SHEET A1 AND |
| | PROVIDE COMPLETE INFORMATION OF EITHER |
| | OPTION. |
| | 7-SPECIFY FASTENERS FOR 2X4 BLOCKING AT |
| | ARCHED OPENINGS. SEC. 104.2.1.2 CITY |
| | AMENDMENTS TO FBC 2001. |
| | 8-PROVIDE COMPLETE KNEE WALL DETAIL AT |
| | ENTRY PORCH. SEC. 104.2.1.2 CITY |
| | AMENDMENTS TO FBC 2001. |
| | 9-SPECIFY 7/8" MIN. STUCCO THICKNESS AT |
| | FRAMED WALLS AS REQ'D BY ASTM C-926. |
| | 10-SPECIFY SAFETY GLASS AS REQUIRED BY |
| | SEC. 2405.2(IF NOT USING IMPACT GLASS) |
| | B)GLASS BLOCK TO HAVE SAFETY GLASS ALSO |
| | IF FACE THICKNESS IS LESS THAN 0.25". |
| | SPECIFY FACE THICKNESS TO BE USED. |
| | 11-SHEET A3: A)CLARIFY IF ATTIC ABOVE |
| | GARAGE AREA IS DESIGNEDFOR STORAGE |
| | OR NOT STORAGE. ATTIC ACCESS W/ LADDER |
| | SUGGESTS ATTIC TO BE USED FOR STORAGE. |
| | IF SO, THEN PROVIDE SPECIFICATIONS. |
| | SEE TABLE 1604.1 FBC 2001. |
| | B)ATTIC LIVE LOAD IS MEASURED IN PSF, |
| | NOT PSI. REVISE NOTE AS REQUIRED. |
| | 12-DRAWINGS ON SHEET A1 ARE NOT LEGIBLE. |
| | 13-PROVIDE ATTIC ACCESS AT GUEST HOUSE. |
| | SEC. 2309.6 FBC 2001. |
| | 14-PROVIDE COMPLETE SECTION THRU BAY |
| | WINDOW. SEC. 104.2.1.2 CITY AMENDMENTS |
| | TO FBC 2001. |
| | 15-PROVIDE COMPLETE LEDGER DETAIL FOR |
| | ROOF TRUSSES @ ENTRY PORCH. SEE PLANS. |
| | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. |
| | 16-PLEASE PROVIDE ONLY THE DETAILS THAT |
| | APPLY TO THIS HOUSE. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | BACK AT 805-6712. |