| 2004-03-15 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 04020656 |
| | ADD: 310 EVERNIA ST |
| | CONT: ANDERON MOORE |
| | TEL: (561) 662-1819 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1)FL BLD CODE 104.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED, |
| | A) PLANS DO NOT INDICATE THE SPACING OF |
| | THE METAL TRUSSES APPROX 5'-6" TO |
| | 6'-0" WHAT TYPE OF SYSTEM WILL ACT |
| | AS INTERMEDIATE FRAMING? |
| | B) PLAN ALSO ARE MISSING WHAT TYPE OF |
| | SHEATHING WILL BE USED FOR THE ROOF |
| | DECK. TYPE IV BLDG. SEE TABLE 600 |
| | (FOOTNOTE "E"). |
| | C) PLANS INDICATE BOTH THE USE OF BAR |
| | JOIST AS WELL AS METAL ROOF TRUSSES? |
| | D) THE BAR JOIST DO NOT GIVE THE CENTER |
| | TO CENTER DIMENSION? |
| | E) PLANS DO NOT INDICATE HOW THE WIRE |
| | LATH WILL BE ATTACHED NOR THE SPACING |
| | OF THE FRAMING MEMBERS? |
| | F) PLANS DO NOT GIVE THE MAGNITUDE OF |
| | LOADS TO BE RESISTED, VERTICAL, |
| | HORIZONTAL NOR GRAVITY, PART OF THE |
| | MAIN WIND-FORCE RESISTING SYSTEM. |
| | G) INDICATE IF THIS STRUCTURE WAS DESIGN |
| | ED AS OPEN? |
| | |
| | 2) AUTOMATIC TELLAR MACHINES 11-4.34 |
| | SEE SUBSECTION 1-5. |
| | |
| | 3) PROVIDE NOC RECORDED WITH THE CLERK |
| | OF COURT BEFORE A PERMIT CAN BE ISSUED. |
| | |
| | 4) FL BLD CODE 1804.2.2 QUESTIONABLE |
| | SOILS, WHERE THE BEARING CAPACITY IS |
| | NOT DEFINETLY KNOWN OR IS IN QUESTION. |
| | WHERE THE BEARING CAPACITY OF THE SOIL I |
| | S NOT DEFINITEY KNOWN, OR IS IN QUESTION |
| | THE BUILDING OFFICIAL MAY REQUIRE EXPLOR |
| | ATIONS, TEST OR OTHER ADEQUATE PROOF AS |
| | TO THE PERMISSIBLE SAFE BEARING |
| | CAPACITY. REQUIRED TEST AND RECOMMENDA- |
| | TIONS SUBMITTED TO VERIFY BEARING CAPA- |
| | CITY SHALL BE CERTIFIED BY A GEOTECH- |
| | NICALREPORT FROM A DESIGN PROFESSIONAL P |
| | ROPERLY LICENSED IN THE STATE OF |
| | FLORIDA. |
| | |
| | 5) BEFORE A PERMIT TO CONSTRUCT CAN BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| | BEACH CO.,THE PERMIT PLANS STAMPED BY |
| | THEM AND THE RECEIPT ATTACHED TO THE |
| | PERMIT APPLICATION. |
| | |
| | LOOK FOR COMMENTS BY THE OTHER PLAN |
| | REVIEW DISCIPLINES THAT MAY BE WRITTEN |
| | ON THE APPLICATION, PLANS, OR ATTACHED |
| | SEPARATELY. WHEN RESUBMITTING PLANS |
| | PLEASE CLEARLY INDICATE THE REVISION AND |
| | REMOVE AND REPLACE ANY PAGES AS NECESS- |
| | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH |
| | THE PLANS WHEN RESUBMITTING PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN |
| | BE FOUND, WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | JIM WITMER |
| | BUILDING PLAN REVIEW |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |