Plan Review Notes
Plan Review Notes For Permit 04020434
Permit Number 04020434
Review Stop B
Sequence Number 1
Notes
Date Text
2004-02-25 00:00:00BUILDING PLAN REVIEW TYPE- II-A BLD
 PERMIT: 04020434BLD#1
 ADD: 800 MALIBU BAY DR
  
 PERMIT: 04020443BLD# 3
 ADD: 780 MALIBU BAY DR
  
 PERMIT:04020444BLD# 4
 ADD: 770 MALIBU BAY DR
  
 PERMIT: 04020445BLD# 5
 ADD: 760 MALIBU BAY DR
  
 PERMIT: 04020452BLD# 10
 ADD: 740 MALIBU BAY DR
  
 PERMIT: 04020454BLD# 11
 ADD: 730 MALIBU BAY DR
  
 CONT: MILLENNIUM GENERAL CONTRACTOR
 TEL: (305)218-7895
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 PERMIT APP/ 1ST REVIEW
 ACTION: DENIED
  
 1) PROVIDE A COPY OF THE VARIANCE RE-
 QUIRED FOR 1014.1.1 BALCONIES, PORCHES
 AND GALLERIES, AN APPROVED BY THE BOARD
 OF ADJUSTMENT & APPEAL.
  
 2) THIS COMMENT APLLIES ONLY TO BLD# 1.
 ALTHOUGH THIS BUILDING SETS OVER THE
 15' FROM THE PROPERTY LINE SATISFYING
 705.1.1.2, CLASSIFYING THE BUILD, TYPE
 VI 1 HR PROTECTED TABLE 600 FOR WALLS
 LOCATED 10'-20' FROM PROPERTY LINE,
 OPENING PROTECTIVES REQUIRED 45 MIN FOR
 OPENINGS < 40% WALL AREA.
  
 3) BUILDINGS 4 & 5 WILL HAVE THE SAME
 ISSUE BECAUSE OF THE LOCATION OF THE
 GAZEBO.TABLE 600 ASSUMED PROPERTY LINES!
  
 4) NOTE THE FIRE RATED TEST REPORT FROM
 D. V. FRYE-TEC FOR HORIZONTAL SLIDING
 WINDOWS WITH A LIMITATION OF 670 SQ IN
 PER FRAME. THE MAXIMUM GLASS LIGHT WIDTH
 OF 32"AND HEIGHT OF 42".NOTE 32X42=1344.
  
 5) PLEASE INDICATE HOW THE HORIZONTAL
 SLIDING UNITS WILL BE SELF CLOSING.
 REQUIRED FOR THE < 20' FROM PROPERTY
 LINE.
 IN CASE OF THE WINDOWS NEXT TO THE
 STAIRWAY INDICATE IF A FIXED FIRE RATED
 WINDOW OR OTHER MEANS OF CODE COMPLIANCE
  
 6) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) LOUVER
 B) TRUSS ANCHORS
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 7) PLEASE DELETE ALL REFRENCES OF SEMCO
 PRODUCTS FROM PLANS, THIS PRODUCT WAS
 BOUGHT OUT IN 1999. THERE IS NO STATE
 APPROVALS FOR THIS PRODUCT!!!!!!!!!!!!!
  
 8) PLANS INDICATE THE USE OF MONIER ROOF
 TILE VS SUBMITTING PRODUCT APPROVAL FOR
 ENTEGRA ROOF TILE??????????/
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026