| 2004-03-04 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 04020164 |
| | ADD: 1315S FLAGLER DR |
| | CONT: COASTAL RECONSTRUCTION |
| | TEL: (904)607-1925 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | 1SR REVIEW |
| | ACTION: DENIED |
| | |
| | 1)FL BLD CODE 104.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED, |
| | THE PLANS DO NOT INDICATE WHAT THE MINI- |
| | MUM BUILDING TYPE IS? DOES THIS STRUC- |
| | TURE HAVE AN ELEVATOR AND DOES IT TRAVEL |
| | TO ALL THREE FLOORS? PLEASE PROVIDE A |
| | FLOOR PLAN FOR THE BUILDING. |
| | |
| | 2) PLANS NEED TO GIVE THE TYPE OF USAGE? |
| | FOR THE REMAINDER OF THIS REVIEW I AM |
| | ASSUMMING R2, DORMITORY. |
| | |
| | 3) THIS BUILDING FALLS UNDER THE TITLE |
| | III OF ADAAG, PUBLIC ACCOMMADATION, |
| | SHALL REMOVE ARCHITECTURAL BARRIERS IN |
| | EXISTING BUILDINGS.SEVERAL JURISDICTIONS |
| | HAVE SUBMITTED THEIR BUILDING CODES FOR |
| | REVIEW BY THE DEPT OF JUSTICE. FLORIDA'S |
| | CODE HAS BEEN CERTIFIED. THE REST OF |
| | THIS REVIEW WILL BE CONSIDERED UNDER |
| | THE FLORIDA ACCESSIBILITY CODE CHAPT 11. |
| | |
| | 4) THIS CODE WILL REQUIRE THE USE OF AN |
| | ELEVATOR 11-4.1.2 NOTHING IN THIS CODE |
| | SHALL BE CONSTRUED TO RELIEVE THE OWNER |
| | OF ANY BUILDING, STRUCTURE OR FACILITY |
| | FROM THE DUTY TO PROVIDE VERTICAL ACCESS |
| | IBILITY TO ALL LEVELS ABOVE OR BELOW THE |
| | OCCUPIABLE GRADE LEVEL. |
| | |
| | 5) 11-9.1 SECTION 11-9 ACCESSIBLE |
| | TRANSIENT LODGING. 11-9,1 HOTELS, MOTELS |
| | INNS, BOARDING HOUSES, DORMITORIES, |
| | RESORTS AND OTHER SIMILAR PLACES OF |
| | TRANSIENT LODGING. SEE ALL SECTIONS |
| | 11-9.1-9.2.2, 11-9.3 AND 11-9.4. |
| | |
| | 6)11-4.1.6(2) DUTY TO PROVIDE AN |
| | ACCESSIBLE PATH OF TRAVEL TO ALTERED |
| | AREAS SHALL BE DEEMED DISPROPORTIONATE |
| | TO THE OVERALL ALTERATION WHEN THE COST |
| | EXCEEDS 20 % OF THE COST OF THE ALTERA- |
| | TION TO THE PRIMARY FUNCTION AREA. |
| | (A)(I) AN ACCESSIBLE ENTRANCE |
| | (II) AN ACCESSIBLE ROUTE |
| | (III) AT LEAST ONE ACCESSIBLE REST- |
| | ROOM FOR EACH SEX OR A SINGLE |
| | UNISEX RESTROOM |
| | (IIII) ACCESSIBLE TELEPHONE |
| | (IV) ELEMENTS SUCH AS PARKING, STOR- |
| | AGE OR ALARMS. |
| | |