2004-03-03 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04020100
 ADD: 401 N DIXIE HWY
 CONT: M. A. C. CONSTRUCTION
 TEL: (786)357-0214
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1ST REVIEW
 ACTION: DENIED
  
 1) TABLE 803.3 MINIMUM INTERIOR FINISH
 CLASSIFICATION; PROVIDE INFORMATION
 BASED ON INTERIOR FINISH REQUIREMENTS
 BASED ON OCCUPANCY: BUSINESS.
  
 2)11-4.13.6 MANEUVERING CLEARENCES
 AT DOORS. MINIMUM MANEUVERING CLEARENCES
 AT DOORS THAT ARE NOT AUTOMATIC OR
 POWER-ASSISTED SHALL BE AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITH
 IN THE REQUIRED CLEARENCES SHALL BE
 CLEAR & LEVEL.
 THE 2 END OFFICES ON THE RIGHT SIDE OF
 THE SHEET DO NOT HAVE 12" CLEAR ON THE
 LATCH SIDE OF THE DOOR.
  
 3) PLANS INDICATE THE LOCKS OR LATCHSETS
 ARE TO MATCH EXISTING. PLANS DO NOT
 INDICATE COMPLIANCE WITH 11-4.13.9
 ACCESSIBLE DOORS: LEVER-OPERATED MECHAN-
 ISMS, PUSH-TYPE MECHANISMS, AND U SHAPED
 HANDLES ARE ACCESSIBLE DESIGNS.
  
 4) PLANS INDICATE WORK ON THE 5TH FLOOR
 THE PERMIT APP DOES NOT INDICATE THIS
 SO SAID WORK HAS BEEN STRUCK FROM PERMIT
 BUILDING PLAN REVIEW