| Plan Review Notes For Permit 04011308 |
| Permit Number |
04011308 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2004-03-02 00:00:00 | DENIED | | | 1.COMPLETE ENERGY CALCULATION FORM | | | AND SIGN 2 COPIES. | | | | | | 2.SUBMIT DETAIL SHOWING HEADERS WITH | | | SIZE AND TYPE OF FRAMING AND TYPE OF | | | STRAPS USED. | | | | | | 3.WINDOW BUCK SHALL COMPLY WITH | | | FBC 1707.4.4.2SUBMIT A DRAWING DETAIL. | | | | | | 4.SUBMIT A SITE PLAN SHOWING NEW | | | STRUCTURE IN RELATIONSHIP TO OTHER | | | EXISTING BUILDINGS SO THAT WE CAN CHECK | | | FOR POSSIBLE TABLE 600 ISSUES. | | | | | | 5.FOUNDATION PLAN... FOOTING STOPS | | | BEFORE EXISTING BUILDING.PLEASE VERIFY | | | | | | 6.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | ANY QUESTIONS PLEASE CALL... | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|