Plan Review Notes
Plan Review Notes For Permit 04011273
Permit Number 04011273
Review Stop M
Sequence Number 1
Notes
Date Text
2004-02-21 00:00:00FAILED
 ----------------------------------------
 BALANCED RETURN AIR IS REQUIRED FROM ALL
 HABITABLE AREAS OF HOUSE PER FBC(M)601.4
  
 THERE IS NO VISIBLE MEANS OF RETURN AIR
 IN THE FOLLOWING AREAS:
  
 1ST FL- ALL AREAS OUTSIDE OF BEDROOMS
 ARE SEPARATED FROM R/A BY POCKET
 DOOR. A SEPARATE MEANS OF RETURN
 IS REQUIRED IN LIBRARY. POCKET
 DOORS SEPARATING FAMILY ROOM
 AND KITCHEN FROM RETURN SHOULD
 ALSO BE ACCOUNTED FOR.
  
 2ND FL- STUDY AND DRESSING AREA SHOW NO
 VISIBLE MEANS OF BALANCED R/A.
  