| Date |
Text |
| 2004-02-19 00:00:00 | DENIED |
| | |
| | 1) THE ENERGY CALCULATION FORM DOES NOT |
| | INCLUDE THE CEILING AREA OF THE COFFERED |
| | CEILINGS. PLEASE CORRECT. SEE FBC |
| | CHAPTER 13 SECTION 604. |
| | |
| | 2) SPECIFY ON THE PLANS THAT THE DOOR |
| | FROM THE GARAGE TO THE CONDITIONED AREA |
| | OF THE STRUCTURE IS INSULATED OR SOLID |
| | CORE AS REQUIRED BY FBC CHAPTER 13 SECT. |
| | 603. |
| | |
| | 3) REVISE SGD BUCK DETAIL ON A4. THE |
| | NOTE SHOULD READ TO FASTEN THROUGH THE |
| | 1X BUCK. FBC 1707.4.4.2. |
| | |
| | 4) THE RIGHT ELEVATION ON A3 HAS THE |
| | WRONG MASONRY OPENING SIZE LISTED FOR |
| | THE OPENING ON THE LEFT. IT IS LISTED AS |
| | 32"X 48" ON THE FLOOR PLAN ON A2. PLEASE |
| | CORRECT. |
| | |
| | 5) CORRECT THE OPENING SIZE FOR #3 ON |
| | THE STORM PANEL INSTALLATION SCHEDULE. |
| | REVISE THE HEIGHT FOR #13 ON THE SCHED. |
| | THE HEIGHT LISTED ON THE PLANS EXCEEDS |
| | 80". |
| | |
| | 6) THE MASONRY OPENING SIZES FOR THE |
| | FIXED GLASS WINDOWS ON THE LEFT |
| | ELEVATION ON A4 FOR WINDOWS #12 & #13 |
| | ARE INNCORRECT. THEY SHOULD BE 64" IN |
| | HEIGHT. PLEASE CORRECT. |
| | |
| | 7) SUBMIT THE ENGINEERED DRAWINGS FOR |
| | THE 16'X8' GARAGE DOOR. THE ONE |
| | SUBMITTED IS FOR A MAXIMUM 9' WIDTH. |
| | |
| | 8) SUBMIT PRODUCT APPROVALS FOR A 16' |
| | LONG MULLION BETWEEN THE 16' WIDE SGD |
| | AND THE TRANSOM AT THE GREAT ROOM. THE |
| | ONE SUBMITTED ONLY LISTS UP TO 12' MULL |
| | LENGTH. OR SPECIFY A LINTEL, STRUCTURAL |
| | STEEL HEADER OR OTHER DESIGN. |
| | |
| | 9)PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |