Plan Review Notes
Plan Review Notes For Permit 04010614
Permit Number 04010614
Review Stop B
Sequence Number 1
Notes
Date Text
2004-02-27 00:00:00BUILDING REVIEW CHECKLIST:
 1-NEED RECORDED NOTICE OF COMMENCEMENT.
 2-PAY IMPACT FEES AND BRING BACK STAMPED
 DRAWINGS AND PAID RECEIPT.
 3-SEE ELECTRICAL COMMENTS REGARDING
 INFORMATION ON DRAINGS TITLE BLOCK.
 CHAPTER 481 FLORIDA STATUTES.
 4-PROVIDE SOIL TEST REPORT.
 5-DESIGN CRITERIA: ADD 30PSF/10PSFFOR
 ATTIC LIVE LOAD AS REQUIRED BY TABLE
 1604.1 FBC 2001.
 6-PROVIDE SPECIFICATIONS FOR ROOF TILE
 FASTENING. SEE SEC. 1606.3 FBC 2001 &
 SEC. 104.2.1.1 CITY AMENDMENTS TO FBC.
 7-SPECIFY SUPPORTS AND SPACING FOR WWM
 IN CONCRETE SLAB AS REQ'D BY SECTION
 1909.3 FBC 2001.
 8-REVISE SPECS FOR ROOF SHEATHING: A)SEE
 TABLE 2306.1 CITY AMENDMENTS TO FBC
 2001 FOR MIN. FASTENER TYPE & SPACING
 REQ'D ACCORD'G TO THE MEAN ROOF HEIGHT
 GREATER THAN 25'.
 B)REVISE ROOF ZONES SHOWN ON FRAMING
 PLANS. SEE FIGURE 1606.2(C) TO INCLUDE
 ROOF ZONE 3.
  
 9-PROVIDE APPROVAL AND SPECS FOR BBQ AS
 REQ'D BY SEC. 2808 FBC 2001.
 10-PROVIDE DETAIL/SPECS FOR INSTALLATION
 OF CEILING AT FAMILY LOGGIA. SEE ASTM
 C-926 AND ASTM C1063 FOR MIN. STUCCO
 THICKNESS AND FASTENER TYPE & SPACING.
 SECTION 2504.2 FBC 2001.
 11-PROVIDE COMPLETE FLORIDA OR LOCAL
 PRODUCT APPROVAL PACKAGE FOR:
 A)FRENCH DOORS WITH TRANSOM ABOVE SINGLE
 ASSEMBLY AS SHOWN ON PLANS.
 B)ALL STRUCTURAL CONNECTORS.
 C)ENTRY DOOR SITE SPECIFIC COMPLETE
 ENGINEERING PACKAGE. SEE CITY OF WPB
 FORM FOR INFORMATION REQUIRED.
 **DRAWINGS FOR FRENCH DOOR-IMPACT BY "LA
 FINESTRA" SHOW WINDOWS, NOT DOORS.
 CLARIFY AS REQUIRED.
 D)FIXED WINDOWS. NEED FLORIDA OR LOCAL
 PRODUCT APPROVAL PACKAGE.
 E)CASEMENT WINDOWS NEED FLORIDA 0R LOCAL
 PRODUCT APPROVAL PACKAGE WITH DRAWINGS
 MATCHING THE REPORT.
 F)PROVIDE FLORIDA OR LOCAL PRODUCT APPRO
 VAL FOR GARAGE DOORS. (CYPRESS CLAD?).
 G)PROVIDE FLORIDA OR LOCAL PRODUCT APPRO
 VAL FOR EXT. SWING DOOR AT GARAGE.
 H)SWINGING DOORS BY "JELD-WEN":PLANS
 CALL FOR IMPACT GLAZING. THIS PRODUCT
 IS FOR NON IMPACT GLASS. CLARIFY.
 **NEED MANUFACTURER'S COMPLETE DRAWINGS.
 **CLARIFY WHERE ARE THESE DOORS GOING TO
 BE INSTALLED.
 **NEED FRENCH DOORS WITH TRANSOM ABOVE
 ALSO AS SHOWN ON PLANS.
 I)NEED FLORIDA OR LOCAL PRODUCT APPROVAL
 PACKAGE FOR ROOF TILE.
 J)QUATROFOIL WINDOW NEED FLORIDA/ LOCAL
 PRODUCT APPROVAL PACKAGE.
 K)NEED FLORIDA OR LOCAL PRODUCT APPROVAL
 FOR WINDOW MULLIONS. SEE PLANS.
 L)NEED FLORIDA OR LOCAL PRODUCT APPROVAL
 FOR RAILINGS.
  
 12-PROVIDE COMPLETE FRAMING DETAIL/SPECS
 FOR QUATROFOIL WINDOWS. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 13-OWES $679.71 FOR UPDATED VALUATION
 AND RADON FEES.
 14-ENERGY CALCULATIONS: A)ORIENTATION &
 NUMBER OF OPENINGS DON'T MATCH PLANS.
 B)OVERHANG LENGTH DON'T MATCH PLANS.
  
 15-SHEET A-1: REVISE/UPDATE NOTES. SEE
 COMMENTS ON PLANS.
 16-SHEET A-5: A)CONNECTOR FOR GIRDER
 TRUSS SHOWN DON'T WORK. SEE PLAN FOR
 COMMENTS.
 B)REVISE NAILING PATTERN SCHEDULE. SEE
 FIGURE 1606.2(C) FBC 2001 AND TABLE
 2306.1 CITY AMENDMENTS TO FBC 2001 FOR
 ZONE 3 & MIN. FASTENER TYPE & SPACING
 WHEN MEAN ROOF HEIGHT IS MORE THAN 25'
 17-SHEET A-6: A)PROVIDE DETAIL SHOWING
 INSTALLATION OF 3 CONNECTORS AT ONE
 POINT AS SPECIFIED FOR CONNECTOR C+D.
 SEE PLANS FOR COMMENTS. CLARIFY WHY
 USING WOOD TO WOOD CONNECTOR FOR WOOD
 TO MASONRY CONNECTION.
 B)UPDATE/REVISE TRUSS ANCHOR SCHEDULE.
 SEE SIMPSON 2004 CATALOGUE OR PROVIDE
 ENGINEERING CALCS FOR FASTENER TYPE &
 NUMBER OTHER THAN THOSE TESTED AND
 PUBLISHED BY SIMPSON.
 C)CLARIFY CONNECTORS SPECIFIED ON
 CONNECTOR NOTES. SEE COMMENTS ON PLANS
  
 18-SHEET A-11: CLARIFY INSTALLATION OF
 JOIST HANGER. SEE COMMENTS ON PLANS.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.