Plan Review Notes
Plan Review Notes For Permit 04010409
Permit Number 04010409
Review Stop B
Sequence Number 1
Notes
Date Text
2004-02-13 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) FBC* 1804.2.2AREA OF QUESTIONABLE
 SOIL.SUBMIT A GEOTECHNICAL REPORT
 TO VERIFY THE SAFE BEARING CAPACITY OF
 THE SOIL.
  
 3)FBC 2405.2THE OVAL FIXED GLASS
 WINDOW IN THE MASTER BATH IS IN A
 'HAZARDOUS LOCATION' AND IS REQUIRED TO
 BE SAFETY GLASS. INDICATE ON THE PLAN.
  
 4) INDICATE THE LOCATION AND SIZE OF THE
 ATTIC ACCESS ON THE FLOOR PLAN. SEE
 FBC 2309.6.
  
 5)1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
 REVISE THE TRUSS ANCHOR SCHEDULE ON
 SHEET 6. SEE CURRENT USP CATALOG FOR
 DOUBLE ANCHOR VALUES. SUBMIT STATE
 PRODUCT APPROVALS FOR THE TRUSS ANCHORS
 SPECIFIED ON THE PLANS.
  
 6)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 FORMS ATTACHMENTED. SUBMIT PROPER FORM
 FOR COLLIER GARAGE DOOR. QUALITY
 ASSURANCE IS REQUIRED.
  
 7) THE SMALL GARAGE DOOR IS NOT COVERED
 BY THE PRODUCT APPROVAL THAT WAS
 SUBMITTED. IT IS SMALLER THAN THE
 MINIMUM DOOR SIZE LISTED ON THE DRAWING.
  
 8) SPECIFY THE MOUNT TYPE AND ANCHORS
 THAT WILL BE USED FOR THE STORM PANELS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714