Plan Review Notes
Plan Review Notes For Permit 04010074
Permit Number 04010074
Review Stop B
Sequence Number 1
Notes
Date Text
2004-02-06 00:00:00DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) THE SURVEY HAS THE WRONG FLOOD ZONE
 LISTED. THE STRUCTURE IS IN A "B" FLOOD
 ZONE. SUBMIT A REVISED SURVEY.
  
 4) THE MAXIMUM HEIGHT ALLOWED BY ZONING
 FOR THIS STRUCTURE IS 33 FEET FROM GRADE
 TO THE HIGHEST POINT OF THE ROOF. THE
 ELEVATIONS INDICATE THAT THE STRUCTURE
 EXCEEDS THIS.
  
 5) SPECIFY THE MEAN ROOF HEIGHT OF THE
 STRUCTURE ON THE PLAN. THIS IS THE
 HEIGHT FROM FINISH GRADE TO THE AVERAGE
 HEIGHT OF THE HIGHEST ROOF WITH A PITCH.
  
 6) A THREE STORY R3 STRUCTURE OF TYPE VI
 CONSTRUCTION IS REQUIRED TO BE SPRINKLED
 OR ONE HOUR PROTECTED. SEE FBC TABLES
 500 AND 600.
  
 7) PROVIDE DETAILS FOR THE THIRD FLOOR
 ATTIC AREA. PROVIDE A CROSS SECTION.
 INDICATE THE EXTERIOR AND INTERIOR
 FINISHES, FRAMING, INSULATION, FLOOR
 SHEATHING, CONNECTORS, ETC. INDICATE ON
 THE PLANS IF THE ROOM WILL BE CONDITION-
 ED SPACE(NOT INDICATED BY ENERGY CALCS).
  
 8) PROVIDE A DETAIL OF THE END WALLS OF
 THE ATTIC ROOM. SHOW SIZE AND SPACING OF
 THE FRAMING, STRAPPING, HEADER SIZE,
 FRAMING FOR ARCH ABOVE THE WINDOW.
  
 9) INDICATE ON THE PLANS THAT THE WALLS
 OF THE STAIRS TO THE THIRD FLOOR ARE
 INSULATED AND THE DOOR IS SOLID OR
 INSULATED AND WEATHER STRIPPED IF THE
 ATTIC ROOM IS NOT INSULATED. FBC CHAPTER
 13.
  
 10) SPECIFY THE SIZE OF THE BUTT GLASS
 WINDOW IN THE BREAKFAST ROOM.
  
 11) STAIRS DO NOT COMPLY WITH FBC
 1007.3.1 EXCEPTION (1). SUM OF TWO
 RISERS AND A TREAD EXCLUSIVE OF NOSING
 SHALL BE NOT LESS THAN 24"OR MORE THAN
 25".
  
 12) SPECIFY THE POSITIVE AND NEGATIVE
 WINDLOAD PRESSURES FOR EACH OF THE
 EXTERIOR OPENINGS.
  
 13) THE FOUNDATION WALL SECTION ON SHEET
 4 IS FOR A STEM WALL AND THE PLANS ARE
 FOR A MONOLITHIC SLAB. PLEASE REVISE.
 SEE SOILS REPORT FOR FOOTER RECOMMENDAT-
 IONS.
  
 14) PROVIDE A CROSS SECTIONAL DETAIL OF
 THE COVERED ENTRY.
  
 15) THE FOUNDATION WALL SECTION ON SHEET
 4 SPECIFIES METAL ROOFING AND THE
 ELEVATION ON SHEET 2 SHOWS CEMENT TILE.
 PLEASE CORRECT.
  
 16) SPECIFY THE SPACING OF THE 5/8" J-
 BOLTS ON THE GARAGE DOOR JAMB DETAIL ON
 SHEET 5.
  
 17) THE WINDOW BUCK AND SILL DETAILS ON
 SHEET 5 SPECIFY 1X P.T. BUCKS AND THE
 TYPICAL WOOD BUCK TO CONCRETE DETAIL
 SPECIFIES 2X P.T. FOR WIDOW AND DOOR
 OPENINGS. PLEASE CLARIFY. SPECIFY THE
 SPACING OF THE T-NAIL FASTENERS.
  
 18) SPECIFY THE UPLIFT VALUES FOR THE
 TRUSSES ON THE ROOF FRAMING PLANS ON
 SHEET 5. SPECIFY THE TRUSS CONNECTORS
 TO BE USED.
  
 19) SPECIFY THE LIVE LOADS FOR THE ATTIC
 AREA AND THE ATTIC. SEE FBC TABLE 1604.1
  
 20) INDICATE THE SIZE AND LOCATION OF
 THE ATTIC ACCESS OPENING FOR THE ATTIC
 ABOVE THE THIRD FLOOR ATTIC ROOM. SEE
 FBC 2309.6.
  
 21)SPECIFY ATTIC VENTILATION AS REQUIRED
 BY FBC 2309.7.
  
 22) SPECIFY HOW THE WATERPROOFING OF THE
 BALCONY ABOVE THE GARAGE WILL BE
 ACCOMPLISHED.
  
 23) PROVIDE A DETAIL OF THE CONCRETE
 BEAM OR LINTEL ABOVE THE GARAGE THAT
 SUPPORTS THE SECOND FLOOR AND ROOF.
  
 24) PROVIDE DETAILS OF THE 2"X 12" BEAM
 THAT SUPPORTS THE FLOOR SYSTEM FOR THE
 SECOND STORY. SPECIFY LUMBER GRADE, NAIL
 SIZE & SPACING. GLUEING, ETC. INDICATE
 THE ATTACMENT OF BEAM AT EXTERIOR
 MASONRY WALLS AND ATTACHMENT OF FLOOR
 TRUSSES TO BEAM.
  
 25) PROVIDE A DETAIL OF THE CANTILEVER
 CONCRETE BEAM ABOVE THE BUTT GLASS
 WINDOWS IN THE BREAKFAST ROOM. SPECIFY
 SIZES AND LOCATION OF STEEL REINFORCING,
 ETC.
  
 26) SPECIFY ON THE PLANS THE LOCATIONS
 AND MATERIAL THAT WILL BE USED FOR THE
 DRAFTSTOPPING OF THE FLOOR/CEILING
 ASSEMBLY INTO AREAS OF NO MORE THAN 500
 SQFT. SEE FBC 2305.2.2.
  
 27) SPECIFY ON THE PLANS HOW THE BALCONY
 RAILS WILL BE ATTACHED TO THE STRUCTURE,
 THE HEIGHT OF THE RAIL AND THE SPACING
 OF THE INTERMEDIATE RAILS. SEE FBC 1015
 AND 1608.2. SHOP DRAWINGS WILL BE
 REQUIRED.
  
 28) SPECIFY THE DIAMETER AND LENGTH OF
 POWER ACTUATED FASTENERS USED TO ANCHOR
 THE BASE OF THE LOADBEARING INTERIOR
 WALL ON SHEET 3.
  
 29) SPECIFY THE CONNECTORS AT THE TOP
 AND BOTTOM OF THE 4"X 4" POST AT THE
 STAIRS SUPPORTING THE SECOND FLOOR.
  
 30)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT.
  
 31) SUBMIT (2) TWO COPIES OF ALL PRODUCT
 APPROVALS. SUBMIT PRODUCT APPROVALS FOR
 THE FOLLOWING:
 - BUTT GLASS WINDOWS IN THE BREAKFAST
 ROOM
 - BAY WINDOW IN THE GREAT ROOM
 - GREENHOUSE WINDOW
 - FRENCH DOORS WITHOUT SIDELITES
 - INSWING ENTRY DOOR WITH SIDELITE
 - OUTSWING DOOR AT GARAGE
 - ARCHED TOP CASEMENT WINDOWS
  
 32) UNLESS ALL GLAZING IS IMPACT RESIST-
 ANT STORM PANELS WILL BE REQUIRED.
 SUBMIT PRODUCT APPROVALS, KEY PLAN AND
 INSTALLATION SCHEDULE FOR STORM PANELS
 IF USED.
  
 33) WINDOWS IN THIRD FLOOR ATTIC ROOM
 MUST MEET EGRESS REQUIREMENTS OF FBC
 1005.4.
  
 34) THE OWNER/AGENT IS REQUIRED TO SIGN
 AND DATE THE ENERGY CALC. FORM. FBC
 CHAPTER 13.
  
 IN ORDER TO EXPEDIATE PLAN REVIEW,
 PLEASE SUBMIT OLD SHEETS WHEN RESUBMITT-
 ING NEW PLANS.
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved