Plan Review Notes
Plan Review Notes For Permit 04010031
Permit Number 04010031
Review Stop B
Sequence Number 2
Notes
Date Text
2004-03-12 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) SUBMIT STATE PRODUCT APPROVAL FOR THE
 SINGLE OUTSWING EXTERIOR DOOR AT BATH #2
  
 4) THE STATE PRODUCT APPROVAL FOR THE
 COLLIER GARAGE DOOR IS LISTED AS VALID-
 ATED. THIS MEANS IT HAS NOT BEEN
 APPROVED. SUBMIT APPROPRIATE PRODUCT
 APPROVAL.
  
 5) SUBMIT STATE OR LOCAL PRODUCT
 APPROVAL FOR 8'X 7' GARAGE DOOR. THE
 INFO FOR THE COLLIER GARAGE DOOR THAT
 WAS SUBMITTED IS LIMITED TO A MINIMUM
 SIZE OF 10'X6'.
  
 6) THE TRUSS ANCHOR SCHEDULE ON SHEET 9
 LISTS A NU-VUE NVSTA 48 CONNECTOR. THE
 STATE PRODUCT APPROVAL SUBMITTED LISTS A
 NVRT 48 OR A NVSTA 22. PLEASE CLARIFY.
  
 7) THE TRUSS ANCHOR SCHEDULE LISTS A
 SIMPSON HUC 412 CONNECTOR WITH 1505# OF
 UPLIFT. THE STATE PRODUCT APPROVAL
 SUBMITTED IS FOR A HU 412 WITH 905# OF
 UPLIFT. PLEASE CLARIFY.
  
 8) THE HTA 16 CONNECTOR IS LISTED IN THE
 ANCHOR SCHEDULE AS A SIMPSON CONNECTOR
 AND IT SHOULD BE USP. PLEASE CORRECT.
  
 9) THE TRUSS TIE DOWN LAYOUT ON SHEET 9
 IS CONFUSING WITH UPPER AND LOWER ROOF
 AND FLOOR TRUSS CONNECTORS ALL SPECIFIED
 ON ONE DRAWING. PLEASE SEPARATE INTO
 LOWER ROOF, UPPER ROOF AND FLOOR TRUSS
 LAYOUT PLANS FOR CLARITY.
  
 10) CLARIFY THE TWO #7 ANCHORS THAT ARE
 SPECIFIED NEAR THE CENTER OF THE GIRDER
 TRUSS AT THE LOWER ROOF ON THE LEFT SIDE
 OF THE LAYOUT.
  
 11) THERE ARE INCONSISTANCES IN THE SIZE
 OF THE BUTT GLASS WINDOWS THROUGHOUT THE
 PLANS AND SITE SPECIFIC PRODUCT APPROVAL
 REAR ELEVATION HAS 40"X72", PLAN DETAIL
 HAS 44"X66" + 42-5/8"X66" AND THE SITE
 SPECIFIC PRODUCT APPROVAL HAS 44"X69" +
 39"X69". PLEASE CORRECT.
  
 12) THE LOCAL PRODUCT APPROVAL SUBMITTED
 FOR THE BUTT GLASS WINDOW IS INCOMPLETE.
 SEE RULE 9B-72. INDICATE METHOD 1 OR
 METHOD 2. INDICATE THE CATEGORY OF
 PRODUCT. THE APPLICANT SHOULD BE THE
 COMPANY ASSEMBLING THE PRODUCT. LIST AN
 APPROVED THIRD PARTY QUALITY ASSURANCE
 ENTITY. LIST ALL THE INFORMATION THAT IS
 REQUIRED FOR AN EVALUATION REPORT FROM A
 FLORIDA PROFESSIONAL ENGINEER AS LISTED
 FOR ITEM #5 IN 9B-72.040. SEE ATTACHMENT
 SPECIFY ANY LIMITATIONS (SUCH AS IMPACT
 PROTECTION REQUIRED). LIST THE
 REQUIREMENTS THE PRODUCT COMPLIES WITH
 INCLUDING CODE SECTION NUMBERS AND
 REFERENCE STANDARDS, SUCH AS FBC 1606,
 1707, 2406.2 AND TAS 202. SUBMIT TEST
 REPORTS, TECHNICAL DOCUMENTS,
 CALCULATIONS, ETC. WHICH IS THE BASIS
 FOR THE RATIONAL ANALYSIS. PROVIDE A
 DETAILED REPORT INDICATING HOW THE
 CONCLUSIONS WERE REACHED. BUTT GLAZING
 ON ARCHITECTURAL PLANS IS AT 90 DEGREE
 ANGLE. SPECIFY WHAT ANGLE OR ANGLES ARE
 ALLOWED BY PRODUCT APPROVAL.
  
 13) SUBMIT PRODUCT APPROVALS, KEY PLAN
 AND INSTALLATION SCHEDULE FOR STORM
 PANELS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714