Plan Review Notes
Plan Review Notes For Permit 04010014
Permit Number 04010014
Review Stop B
Sequence Number 2
Notes
Date Text
2004-03-31 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
  
 1.)ITEMS #1, 3, 4, 5, 6, 7, 8 ON THE
 PREVIOUS LIST WERE NOT ADDRESSED (NOC,
 HISTORIC, SF ON APP, FEES, SIGN OWNER/
 AGENT LINE OF ENERGY CALC, RECEIPT FOR
 IMPACT FEES).
  
 2.)THE PRODUCT APPROVAL SUBMITTED FOR
 THE FRONT DOOR IS FOR A NON-IMPACT
 GLAZED DOOR.THE PLAN SHOWS AN OPAQUE
 DOOR.ONE MEANS OF ESCAPE IN THE EVENT
 OF A HURRICANE MUST BE PROVIDED, FBC
 1005.4.5.ALL OF THE EXTERIOR DOORS
 ARE GLAZED REQUIRING SHUTTERS, SO NO
 MEANS OF ESCAPE HAS BEEN PROVIDED.
 ADDRESS.
  
 3.)THE STANLEY DOOR FLORIDA PRODUCT
 APPROVAL NUMBER IS 1397.SUBMIT TWO
 LEGIBLE COPIES OF THE TEST REPORT.
 THE TEST REPORT IS AVAILABLE FOR
 DOWNLOAD FROM WWW.FLORIDABUILDING.ORG
 OR WWW.MIAMIDADE.GOV.
  
 4.)SEE THE PREVIOUS LIST, ITEM #13.
 IF THIS FORM, ENCLOSED, IS NOT COMPLETED
 THEN A SEPARATE PERMIT FOR HURRICANE
 SHUTTERS WILL BE REQUIRED.
  
 5.)THE TAMKO ROOF PRODUCT APPROVALS
 SUBMITTED ARE FOR A POURED GYPSUM DECK.
 THE APPLICATION FOR THIS JOB IS A
 WOOD DECK.THE GAF PRODUCT APPROVALS
 SUBMITTED ARE CODE COMPLIANT.
  
 6.)THE MODEL 180/280/381, 16' IS
 HIGHLIGHTED ON THE GARAGE DOOR PRODUCT
 APPROVAL, SEE SHEET 3 OF 9.THIS
 PRODUCT HAS A DESIGN LIMITATION OF -37,
 THE DESIGN PRESSURE FOR THE GARAGE DOOR
 IS -39.ADDRESS.
  
 7.)WINDOWS ANCHORS DETAIL, SHEET 7,
 STILL HAVE A 2" TAPCON.WHEN USING A
 1X BUCK, THE TAPCON IS TO HAVE A 1 1/4"
 EMBEDMENT THROUGH THE CONCRETE, SEE
 THE PRODUCT APPROVAL AND FBC1707.4.4.2.
  
 8.)THE PREMDOOR ENTRY DOOR PRODUCT
 APPROVAL SUBMITTED IS FOR AN INSWING
 DOOR, PLAN SPECIFIES OUTSWING.
  
 9.)THE FOLLOWING PRODUCT APPROVALS
 WERE NOT SUBMITTED:SLIDING GLASS DOORS
 MULLIONS, ARCHED FIXED WINDOW, FRONT
 DOOR.
  
 10.) THE NOC IS EXPIRED (OVER 90 DAYS
 WITHOUT COMMENCING WORK), FS713.13.
 THE SAME DOCUMENT CAN BE REFILED WITH
 A NEW DATE AT THE CLERK'S OFFICE.
  
 11.)SEE PREVIOUS LIST, SHEET 7
 SPECIFIES A 2' OVERHANG.ALSO REFERS
 TO SFC, GOVERNING CODE IS FBC2001.