| Date |
Text |
| 2004-03-31 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 |
| | |
| | 1.)ITEMS #1, 3, 4, 5, 6, 7, 8 ON THE |
| | PREVIOUS LIST WERE NOT ADDRESSED (NOC, |
| | HISTORIC, SF ON APP, FEES, SIGN OWNER/ |
| | AGENT LINE OF ENERGY CALC, RECEIPT FOR |
| | IMPACT FEES). |
| | |
| | 2.)THE PRODUCT APPROVAL SUBMITTED FOR |
| | THE FRONT DOOR IS FOR A NON-IMPACT |
| | GLAZED DOOR.THE PLAN SHOWS AN OPAQUE |
| | DOOR.ONE MEANS OF ESCAPE IN THE EVENT |
| | OF A HURRICANE MUST BE PROVIDED, FBC |
| | 1005.4.5.ALL OF THE EXTERIOR DOORS |
| | ARE GLAZED REQUIRING SHUTTERS, SO NO |
| | MEANS OF ESCAPE HAS BEEN PROVIDED. |
| | ADDRESS. |
| | |
| | 3.)THE STANLEY DOOR FLORIDA PRODUCT |
| | APPROVAL NUMBER IS 1397.SUBMIT TWO |
| | LEGIBLE COPIES OF THE TEST REPORT. |
| | THE TEST REPORT IS AVAILABLE FOR |
| | DOWNLOAD FROM WWW.FLORIDABUILDING.ORG |
| | OR WWW.MIAMIDADE.GOV. |
| | |
| | 4.)SEE THE PREVIOUS LIST, ITEM #13. |
| | IF THIS FORM, ENCLOSED, IS NOT COMPLETED |
| | THEN A SEPARATE PERMIT FOR HURRICANE |
| | SHUTTERS WILL BE REQUIRED. |
| | |
| | 5.)THE TAMKO ROOF PRODUCT APPROVALS |
| | SUBMITTED ARE FOR A POURED GYPSUM DECK. |
| | THE APPLICATION FOR THIS JOB IS A |
| | WOOD DECK.THE GAF PRODUCT APPROVALS |
| | SUBMITTED ARE CODE COMPLIANT. |
| | |
| | 6.)THE MODEL 180/280/381, 16' IS |
| | HIGHLIGHTED ON THE GARAGE DOOR PRODUCT |
| | APPROVAL, SEE SHEET 3 OF 9.THIS |
| | PRODUCT HAS A DESIGN LIMITATION OF -37, |
| | THE DESIGN PRESSURE FOR THE GARAGE DOOR |
| | IS -39.ADDRESS. |
| | |
| | 7.)WINDOWS ANCHORS DETAIL, SHEET 7, |
| | STILL HAVE A 2" TAPCON.WHEN USING A |
| | 1X BUCK, THE TAPCON IS TO HAVE A 1 1/4" |
| | EMBEDMENT THROUGH THE CONCRETE, SEE |
| | THE PRODUCT APPROVAL AND FBC1707.4.4.2. |
| | |
| | 8.)THE PREMDOOR ENTRY DOOR PRODUCT |
| | APPROVAL SUBMITTED IS FOR AN INSWING |
| | DOOR, PLAN SPECIFIES OUTSWING. |
| | |
| | 9.)THE FOLLOWING PRODUCT APPROVALS |
| | WERE NOT SUBMITTED:SLIDING GLASS DOORS |
| | MULLIONS, ARCHED FIXED WINDOW, FRONT |
| | DOOR. |
| | |
| | 10.) THE NOC IS EXPIRED (OVER 90 DAYS |
| | WITHOUT COMMENCING WORK), FS713.13. |
| | THE SAME DOCUMENT CAN BE REFILED WITH |
| | A NEW DATE AT THE CLERK'S OFFICE. |
| | |
| | 11.)SEE PREVIOUS LIST, SHEET 7 |
| | SPECIFIES A 2' OVERHANG.ALSO REFERS |
| | TO SFC, GOVERNING CODE IS FBC2001. |