Plan Review Notes
Plan Review Notes For Permit 04010014
Permit Number 04010014
Review Stop P
Sequence Number 1
Notes
Date Text
2004-01-15 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FLA. ADMIN. CODE
 FLA. STATUTES.
  
 1) SHT 6/7 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS.
 A) MASTER BATH - W/C SHALL BE VENTED BY
 WET VENT AND BE TIED INTO THE BATHROOM
 GROUP. PUMPING ACTION FROM WASH MACHINE
 WILL EFFECT WATER CLOSET TRAP SEAL.
 B) MASTER BATH - NO DRY HORIZONTAL DRY
 VENTS ALLOWED. SECTION 905.3
 C) TUB NOT VENTED IN SECOND BATH. SEC-
 TION 901.2.1
 D) SEE RED LINE CORRECTIONS ON PLUMBING
 LAYOUT AND RISER DIAGRAM.
 2) PLANS SUBMITTED BY AN ENGINEER SHALL
 BE SIGNED, SEALED AND DATED BY THE
 ENGINEER. FAC 61G15-23.002(1) & FS 471
  
 REVIEW BY KEN STEVENS