Plan Review Notes
Plan Review Notes For Permit 04010010
Permit Number 04010010
Review Stop P
Sequence Number 3
Notes
Date Text
2004-05-28 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FLORIDA STATUTES
  
 A) FROM PREVIOUS REVIEWS:
 2) IF TOILET ROOMS ARE PROVIDED, THEN
 EACH PUBLIC AND COMMON USE TOILET ROOM
 SHALL COMPLY WITH 11-4.22. SUBMIT A DE-
 TAIL SHOWING COMPLIANCE WITH 11-4.16,
 11-4.19, AND 11-4.22 AND ALL SUBSECTIONS
 11-4.1.3(11).
 - HEIGHT OF TOILET NOT SHOWN 11-4.16.3,
 CLEAR FLOOR SPACE/TURNING AREA 11-4.16.2
 11-4.22.3. GRAB BARS NOT SHOWN IN TOILET
 ROOM BY KITCHEN 11-4.16.4, CLEAR FLOOR
 SPACE FOR TOILETS 11-4.16.2, CLEAR FLOOR
 SPACE FOR LAV IN TOILET BY KITCHEN AREA
 11-4.19.3, EXPOSED PIPES AND SURFACES
 11-4.19.4, DOORS SHALL NOT SWING INTO
 THE CLEAR FLOOR SPACE OF ANY FIXTURE
 11-4.22.2(1).
 3) SHT E-1 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE, EXTRA VENT LINE OFF LAV
 STACK IS A HORIZONTAL DRY VENT AND IS
 NOT REQUIRED. DELETE FROM RISER DIAGRAM.
 SECTION 905.3 - 704.5
  
 INFORMATIONAL: SEE ATTACHED SHEET FOR
 DESIGN PROFESSIONAL CONCERNING FLORIDA
 STATUTE 553.80(2)(B).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]