2004-05-07 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04010010
 ADD: 320 PINE ST
 CONT: BAINES BUILDING
 TEL: (561)635-6935
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 2ND REVIEW
 ACTION: DENIED
  
 1)CHANGE OF OCCUPANCY: THE ENGINEER TO
 PROVIDE INFORMATION TO BE ABLE TO CERTI-
 FY THE FLOOR LOAD TO 50LBS. PROVIDE
 INFORMATION FOR THE FLOOR JOIST, SIZE,
 SPACING, SPECIES OF LUMBER, GRADE AND
 CLEAR FLOOR SPAN, PROVIDE CALCULATIONS.
  
 2) COMMENT 3 FROM 1ST REVIEW: INDICATE C
 OMPLIANCE WITH ACCESSIBILITY CODE, RAMPS
 FOR THE ACCESSIBLE ENTRANCE.
 2A) PLANS INICATE A RAMP IN THE REAR OF
 PROPERTY WITH ACCESSIBLE PARKING LOT
 AND ACCESS ISLE. THE ACCESS ISLE DOESN'T
 ALIGN WITH THE WALK, HAVING THE PERSON
 WHEEL THROUGH THE AREA FOR THE PARKED
 CAR.
 2B) PLANS DO NOT GIVE RAMP REQUIREMENTS:
 11-4.8.4.(2) LANDINGS. ALL LANDINGS
 ON RAMPS SHALL NOT BE LESS THAN 60"
 CLEAR, & THE BOTTOM OF EACH RAMP SHALL
 HAVE NOT LESS THAN 72" OF STRAIGHT &
 LEVEL CLEARENCE.
 2C) THE PLANS DO NOT GIVE A REAR ELEVA-
 TION. THERE CAN BE NO STAIRS FOR THE ACC
 ESSIBLE ROUTE. THE MOST CHANGE IN GRADE
 CAN BE 1/4" WITHOUT THE USE OF A RAMP.
 2D) FRONT ENTRY SIGNAGE REQUIRED:
 11-4.1.6(H) IF A PARTICULAR
 ENTRANCE IS NOT MADE ACCESSIBLE, APPRO-
 PRIATE ACCESSIBLE SIGNAGE INDICATING THE
 LOCATION OF THE NEAREST ACCESSIBLE
 ENTRANCE(S) SHALL BE INSTALLED AT OR
 NEAR THE INACCESSIBLE ENTRANCE, SUCH
 THAT A PERSON WITH DISABILITIES WILL
 NOT BE REQUIRED TO RETRACE THE APPROACH
 ROUTE FROM THE INNACCESSIBLE ENTRANCE.
  
 3) COMMENT 5 FROM PREVIOUS REVIEW:
 FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) NEW WINDOWS
 B) EXTERIOR DOORS IF REPLACED
 PLANS ON 1ST REVIEW INDICATED NEW WIN-
 DOWS NOTHING IS MENTIONED?
 PLANS ON THE 1ST REVIEW DIDN'T ADDRESS
 IF THE DOORS WERE TO BE REPLACED? PLEASE
 GIVE A RESPONCE!!
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 4) TABLE 803.3 MINIMUM INTERIOR FINISH
 CLASSIFICATION; PROVIDE INFORMATION
 BASED ON INTERIOR FINISH REQUIREMENTS
 BASED ON OCCUPANCY
  
 5)1204.2 SURROUNDING MATERIALS;
 THE WALLS & FLOORS OF ALL PUBLIC REST-
 ROOMS SHALL BE LINED WITH NONABSORBANT
 MATERIALS TO A HEIGTH OF 4'-0" ABOVE THE
 FLOOR.
  
 6)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026