Plan Review Notes
Plan Review Notes For Permit 04010010
Permit Number 04010010
Review Stop P
Sequence Number 2
Notes
Date Text
2004-05-11 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 A) FROM PREVIOUS REVIEW: COMMENTS NOT
 ADDRESSED TO CODE SATISFACTION. NUMBER
 OF COMMENT FROM FIRST REVIEW TO STAY THE
 SAME TO AVOID CONFUSION.
 2) IF TOILET ROOMS ARE PROVIDED, THEN
 EACH PUBLIC AND COMMON USE TOILET ROOM
 SHALL COMPLY WITH 11-4.22. SUBMIT A DE-
 TAIL SHOWING COMPLIANCE WITH 11-4.16,
 11-4.19, AND 11-4.22 AND ALL SUBSECTIONS
 - SECTION 11-4.1.3(11). RESPONSE NOTED,
 BUT HEIGHT OF TOILET NOT SHOWN 11-4.16.3
 CLEAR FLOOR SPACE/TURNING AREA 11-4.16.2
 GRAB BARS NOT SHOWN IN TOILET ROOM BY
 KITCHEN 11-4.16.4, CLEAR FLOOR SPACE FOR
 LAV 11-4.19.3, EXPOSED PIPES & SURFACES
 11-4.19.4, DOORS SHALL NOT SWING INTO
 THE CLEAR FLOOR SPACE FOR ANY FIXTURE
 11-4.22.2(1).
 3) SHT E-1 SANITARY RISER DIAGRAM DOES
 NOT REFLECT THE FLOOR PLAN. THE ACCESSI-
 BLE TOILET ROOM SHOULD BE LOCATED ON THE
 LEFT SIDE OF THE BLDG. DRAIN. IF THE
 BUILDING HAS TWO BLDG. DRAINS THEN A C/O
 IS REQUIRED AS EACH BLDG. DRAIN EXITS
 THE BLDG. SECTION 708.3.5 - REMOVE THE
 DRINKING FOUNTAIN FROM THE SANT. RISER
 DIAGRAM, HAND DRAWN CHANGES TO A SIGNED
 AND SEALED SET OF PLANS IS NOT APPROVED.
 4) KITCHEN SINK SHALL COMPLY WITH SECT-
 ION 11-4.24 AND ALL SUBSECTIONS. CLEAR
 FLOOR SPACE FOR SINK IS NOT SHOWN. SEE
 SECTION 11-4.24.5
 NEW COMMENT......................
 1B) ENGINEERS SHALL SIGN PLAN WITH A
 SIGNATURE. PER FBPE'S RULING INITIALS
 ARE NOT ACCEPTABLE.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]