| 2004-04-09 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 04010010 |
| | ADD: 320 PINE ST |
| | CONT: BAINES |
| | TEL: (561)635-6935 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | REVISION |
| | ACTION: DENIED |
| | |
| | 1) CHANGE OF OCCUPANCY 3401.2.2.2 |
| | CHANGES IN OCCUPANCY OF ANY EXISTING |
| | BUILDING SHALL NOT BE MADE UNTIL A REVIS |
| | ED CERTIFICATE OF OCCUPANCY HAS BEEN |
| | ISSUED BY THE BUILDING OFFICIAL |
| | CERTIFYING THAT THE FLOORS ARE SUITABLE |
| | FOR THE LOADS CHARACTERISTICS OF THE |
| | PROPOSED OCCUPANCY. |
| | 2) 3401.3 THE BUILDING IS TO CONFORM TO |
| | THE PROVISIONS OF THE TECHNICAL CODE AND |
| | OTHER APPLICABLE LAWS AND ORDINANCES |
| | FOR SUCH OCCUPANCY. |
| | 3) INDICATE COMPLIANCE WITH ACCESSIBIITY |
| | CODE, RAMPS FOR ACCESSIBLE ENTRANCE. |
| | 4)FL. BLD CODE 1606.1.7 THE FOLLOWING |
| | INFORMATION RELATED TO WIND SHALL BE |
| | SHOWN ON THE CONSTRUCTION DRAWINGS, |
| | 1)- BASIC WIND SPEED, MPH |
| | 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| | CATEGORY |
| | 3)- WIND EXPOSURE |
| | 4)- INTERNAL PRESSURE COEFFICIENT, |
| | 5)- COMPONENTS & CLADDING, THE DESIGN |
| | WIND PRESSURES IN TERMS OF PSF. |
| | 5) FL BLD CODE 1606.1.5: COMPONENTS & |
| | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| | OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| | TESTING REPORTS,MISSING REPORTS ARE AS |
| | FOLLOWS: |
| | A) NEW EXTERIOR WINDOWS |
| | B) EXTERIOR DOORS IF REPLACED? |
| | 6) PLANS INDICATE OCCUPANCY IS FOR R3, |
| | CHANGE TO BUSINESS. |
| | 7) TABLE 803.3 MINIMUM INTERIOR FINISH |
| | CLASSIFICATION; PROVIDE INFORMATION |
| | BASED ON INTERIOR FINISH REQUIREMENTS |
| | BASED ON OCCUPANCY |
| | 8)1204.2 SURROUNDING MATERIALS; |
| | THE WALLS & FLOORS OF ALL PUBLIC REST- |
| | ROOMS SHALL BE LINED WITH NONABSORBANT |
| | MATERIALS TO A HEIGTH OF 4'-0" ABOVE THE |
| | FLOOR. |
| | 9)BEFORE A PERMIT TO CONSTRUCT, MAY |
| | BE ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | LOOK FOR COMMENTS BY THE OTHER PLAN |
| | REVIEW DISCIPLINES THAT MAY BE WRITTEN |
| | ON THE APPLICATION, PLANS, OR ATTACHED |
| | SEPARATELY. WHEN RESUBMITTING PLANS |
| | PLEASE CLEARLY INDICATE THE REVISION AND |
| | REMOVE AND REPLACE ANY PAGES AS NECESS- |
| | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH |
| | THE PLANS WHEN RESUBMITTING PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN |
| | BE FOUND, WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | JIM WITMER |
| | BUILDING PLAN REVIEW |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |