Plan Review Notes
Plan Review Notes For Permit 04010005
Permit Number 04010005
Review Stop B
Sequence Number 1
Notes
Date Text
2004-02-06 00:00:00BUILDING PLAN REVIEW
 PLAN REVIEW- ***(4)UNIT BUILDING***
 PERMIT: 04010005
 ADD: 1100 N CONGRESS
 CONT:WCI COMMUNITIES
 CONTACT PERSON: DOUG BERK
 TEL: (561)262-3684
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ARCH:WCI ARCHITECTURE & LAND PLANNING IN
 CONTACT: PETER SYNOYANNIS
 (954) 575-4200
  
  
 1ST REVIEW
  
 NOTE: THIS REVIEW AFTER SPEAKING WITH
 PETER SYNOYANNIS WILL BE DONE AS A R-2,
 APARTMENT OR CONDOMINIMUMS.
 IF THESE UNITS ARE TO BE SOLD AS
 CONDOMINIMUMS THE CITY WILL NEED A
 FILED COPY OF THE DECLARATION OF
 CONDOMINIMUM BEFORE A CERTIFICATE OF
 COMPLETION SHALL BE ISSUED.
  
 NOTE: IF THESE UNITS ARE REPLATTED INTO
 TRUE TOWNHOUSE UNITS, THERE ARE MANY
 VIOLATION THAT WOULD REQUIRE REDESIGN
 BEFORE A CERTIFICATE OF OCCUPANCY WOULD
 BE ALLOWED TO BE ISSUED!
  
 1) 105.3 CITY ADMINISTRATIVE CODE,
 RESIDENT INSPECTOR TO BE REQUIRED.
 CONTACT HAROLD PISKURA @ 805-6711 FOR
 MORE INFORMATION AS TO REQUIREMENTS FOR
 SEPERATION OF C.O.-ED BUILDINGS &
 CONSTRUCTION, REQUIRED STRUCTURAL
 INSPECTIONS AND PHASING.
  
 2)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 A SITE PLAN INDICATING ALL SITE
 AMENITIES WITH DIMENSIONS BETWEEN
 BUILDINGS TO BE ABLE TO CALCULATE THE
 ASSUMED PROPERTY LINE BETWEEN
 BUILDINGS,SEE TABLE 600. THIS CAN'T BE
 ACHIEVED UNDER THIS REVIEW!!!!!!!!
  
 3) PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
 PLANS ARE TO BE SIGNED WITH A
 FULLSIGNATURE FROM THE ARCHETECT OF
 RECORD
 PER 481.221 WITH A MINIMUM OF FIRST AND
 LAST NAME AS SHOWN ON THE ARCHITECTS'
 LICENSE, FAC 61G1-16.003
  
 4) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 WHERE THE BEARING CAPACITY OF THE SOIL
 IS NOT DEFINITEY KNOWN, OR IS IN
 QUESTIONTHE BUILDING OFFICIAL MAY
 REQUIRE EXPLORATIONS, TEST OR OTHER
 ADEQUATE PROOF AS TO THE PERMISSIBLE
 SAFE BEARING
 CAPACITY. REQUIRED TEST AND RECOMMENDA-
 TIONS SUBMITTED TO VERIFY BEARING CAPA-
 CITY SHALL BE CERTIFIED BY A GEOTECHNI-
 CAL REPORT FROM A DESIGN PROFESSIONAL
 PROPERLY LICENSED IN THE STATE OF
 FLORIDA.
  
 5) FL BLD CODE CHAP 13 ENERGY EFFICENCY
 PROVIDE ENERGY CALS/ W MANUAL "J"
  
 6) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 7)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 ****IMPACT FEES INCREASE MARCH 1,2004,
 APPLICATION FOR PERMIT TO NOT BE
 AFFECT-ED BY THIS INCREASE WILL NEED TO
 BE
 APPLIED FOR NO LATTER THAN FEBRUARY 27,
 2004 AT 4:00PM*****
  
 8) FAIR HOUSING, 1. ACCESSIBLE ROUTE,
 INDICATE ON THE SITE PLAN, THE
 ACCESSIBLE ROUTE TO ALL ELEMENTS,
 INCLUDING CLUBHOUSE, GAZEBOES,
 DUMPSTERSPOOLS, PARKING, AND TO PUBLIC
 TRANSPOR- TATION.
 9) PROVIDE ADDITIONAL INFORMATION FOR
 FAIR HOUSING WHICH METHOD WILL BE USED
 FOR BATHROOMS TYPE A OR B. INDICATE THE
 LOCATIONS BACKING WILL BE REQUIRED, ETC.
 THE PRIMARY ENTRY DOOR OF COVERED
 DWELLING UNITS IS PART OF PUBLIC AND
 COMMON USE SPACES, THEREFORE, IT MUST
 BEON AN ACCESSIBLE ROUTE & BE
 ACCESSIBLE, I.E., MEET THE ANSI
 REQUIREMENTS OF
 4.13 DOORS. ANSI 4.13.9 LEVER OR OTHER
 EASY USE DOOR HARDWARE.
 PRIMARY ENTRY DOORS TO COVERED
 UNITS MUST BE ON AN ACCESSIBLE ROUTE,
 THRESHOLDS AT THESE DOORS MUST BE NO
 HIGHER THAN 3/4" AND MUST BE BEVELED
 WITH A SLOPE NO GREATER THAN 1:2.
 ALSO PROVIDE INFORMATION ON THE
 HARDWAREFOR THE FRONT ENTRY DOORS.
  
 10) SHEET A-1 NOTE 24 INDICATES VENTS
 REQUIRED @ 60" SEE MECH TABLE 403.3
 GARAGES SEPERATE FOR EACH DWELLING,
 100CFM PER VEHICLE. CORRECT GARAGE NOTE
 ALSO!
  
 11) SHEET A-1 FLOOR PLAN NOTE (6)
 WPB AMENDMENT 2111.1.9 WATERSTOP. WHERE
 THE EXTERIOR WALL MASONARY UNITS BEAR
 ONA CONCRETE FLOOR SURFACE, A 1.5"
 RECESS SHALL BE PROVIDED TO MINIMIZE
 WATER
 INTRUSION INTO FINISHED AREAS.
  
 12)FL BLD CODE 2405.2 HAZARDOUS
 LOCATIONPROVIDE SAFETY GLASS FOR THIS
 LOCATION: SHEET A-4 WINDOWS 6 & 9.SEE
 2405.2.1(3)
  
  
 13) SHEET A-10 TYP DETAIL 2 STORY AT
 GARAGE MISSING FLOOR INSULATION.
  
 14) PLANS MAY WANT TO CLARIFY WINDERS:
 1007.8.1 WINDERS SHALL HAVE A
 MINIMUM TREAD DEPTH OF 6" AT THE
 NARROW-EST EDGE & SHALL HAVE A MINIMUM
 TREAD
 DEPTH OF 11" AT A POINT 12" FROM THE
 NARROW EDGE. WINDERS SHALL BE PERMITTED
 TO BE USED AS A COMPONENT IN MEANS OF
 EGRESS WITHIN A DWELLING UNIT.
  
 15) SHEET A-11 SECTION 3& 4 INDICATE
 USEOF SHEATHING PER SPEC?
  
 16) SAME DETAILS ADD INFO ON THE SOFFIT
 WIRE LATH? IF HI-RIB IS TO BE USED SEE:
 2504.2.2 INSTALLATION OF EXTERIOR
 LATHING AND FRAMING SHALL COMPLY WITH
 ASTM C-1063.
  
 17) A-12 FALSE CHIMNEY DETAIL: NO
 INFORMATION ON ANCHORS NOR HOW FAR THE
 VERTICAL SUPPORTS GO OR FASTENED? NO
 DETAIL ON "S" PAGES.
  
 18)FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) WINDOWS
 B) SWING DOORS GLAZED OR SOLID
 C) OVERHEAD DOORS
 D) MULLIONS
 E) STORM SHUTTERS SEE CITY POLICY
 "LARGE PROJECT"
 F) ROOFING
 G) STRUCTURAL COMPONENTS- WOOD
 CONNECTORS, ANCHORS SEE RULE 9B-72
  
 *******IMPORTANT********
 19) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATIONPLEASE SEE THE STATE WEBSITE
 AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL FORM
 PER RULE 9B-72. SEE ATTACHMENT.
  
 20)PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE
 USEDFOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
  
 21)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE
 INSTALLATIONSCHEDULE SUMMARIZING &
 IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL
 PRES-SURE ZONES, SLAT TYPES, ETC.,
 SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 22) SEE CITY IMPLEMENTATION STANDARD
 ITEM# 13"THE PRE-STORM PREPARATION
 PLAN"SEE ATTACHMENT.ITEM# 14 STORM SHUT-
 TERS NOT ALLOWED ON THE 2ND FLOOR.EITHER
 IMPACT RESISTANT GLAZING OR PERMANENTLY
 AFFIXED PROTECTION.
  
 23)1707.4.4.2 TAPERED BUCKS:
 SHALL EXTEND BEYOND THE INTERIOR FACE
 OF THE WINDOW OR DOOR FRAME SUCH THAT
 FULL SUPPORT OF THE FRAME IS SUPPORTED.
 THIS IS FOR BOTH WINDOWS AND DOORS!
  
 24) S-1 MONO SLAB REIN:
 FL BLDG 1909.3 (EXEPTION# 2)
 CONCRETE SLABS ON GRADE CONTAINING 6X6/
 W1.4XW1.4 WELDED WIRE REINFORCEMENT
 FABRIC LOCATED IN THE MIDDLE TO THE
 UPPER 1/3RD OF THE SLAB SHALL BE SUP-
 PORTED BY APPROVED MATERIALS OR
 SUPPORTSAT SPACING NOT TO EXCEED 3 FT
 OR IN
 ACCORDANCE WITH MANUFACTURER'S SPEC.
  
 25)1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD
 LOADARE INVESTIGATED IN LOAD
 COMBINATIONS OF1609.4.1 OR 1609.4.2,
 THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE
 EFFECTSFROM THE LOAD COMBINATION OF THE
 DEAD
 LOAD PLUS THE LOAD PRODUCING THE
 LARGESTEFFECTS. RE-EVALUATE TRUSS
 ANCHORSCHEDULE. USE CURRENT SIMPSON
 "HIGH WINDEDITION, 11/2002.
 UPDATE ANCHOR TYPES, HUGHES IS NO
 LONGER IN BUSINESS,NOW USP!NEW VALUES!
  
 26) SHEET S-2/ S-5 BUCKETS & BRACKET
 DETAILS REQUIRE PRODUCT TESTING REPORTS
 EITHER STATEWIDE OR SITE SPECIFIC
 REPORT!RULE 9B-72.010(29)(G)STRUCTURAL
 COMPONENTS.
 27) S-3 DOOR & WINDOW WIND PRESSURE
 CHART WITH WRONG WALL AREA ZONES 1 & 2
 ARE ROOF ZONES, SHOULD READ 4 & 5 FOR
 THE INTERIOR AND END ZONES.
  
 28) SHEET S4 DETAIL (1)INDICATES A
 GABLE END TRUSS. THERE IS NO LATERAL
 BRACING ON THE GABLE TRUSS. PROVIDE THE
 TRUSS ENGINEERING SHEETS WITH ALL LOAD-
 ING CASES. TRUSS ENGINEERING TO BE
 SIGNED AND SEALED.
  
 29) S-3 NOTE NO MENTION OF THE TRUSS
 BOTTOM LIVE LOAD OF 10 LBS LIVE LOAD,
 TABLE 1604.1 ATTICS WITHOUT STORAGE.
  
 30)FL BLD CODE 2309.6 ATTIC ACCESS, PRO-
 VIDE ATTIC ACCESS 20"X36".
  
 31) 1503.4.4 PROTECTION AGAINST DECAY &
 TERMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 32)301.13.1 GROUND MOUNTED A/C UNITS:
 GROUND-MOUNTED UNITS FOR R3 RESIDENTIAL
 APPLICATIONS MAY BE ANCHORED WITH # 14
 SCREWS WITH GASKETED WASHERS ACCORDING
 TO THE FOLLOWING:
 1) FOR UNITS WITH SIDES LESS THAN 12",
 ONE SCREW SHALL BE USED AT EACH SIDE OF
 THE UNIT.
 2) FOR UNITS BETWEEN 12" & 24", TWO
 SCREWS SHALL BE USED PER SIDE.
 3) FOR UNITS BETWEEN 24" & 36", THREE
 SCREWSSHALL BE USED PER SIDE.
 4) FOR UNITS GREATER THAN 36" OR 5 TONS
 ANCHORAGE SHALL BE DESIGNED IN ACCOR-
 DANCE WITH 301.13 MECH (140 MPH).
  
 33) GARAGE SWING DOOR NOT LISTED ON
 SCHEDULE, 3/4 RATING REQUIRED 411.2.6,
 705.1.3.5 FIRE DOORS SHALL BE EQUIPPED
 WITH AN APPROVED CLOSER.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026