| Date |
Text |
| 2004-02-25 00:00:00 | DENIED |
| | |
| | 1) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | |
| | 2) SUBMIT A SIGNED AND SEALED COPY OF |
| | THE SOIL REPORT. 61G15-35 FAC AND CITY |
| | AMENDMENTS TO FBC 1804.2.2. |
| | |
| | 3) THE FLOOR PLAN ON SHEET A2 SPECIFIES |
| | GLASS BLOCK IN BATH #3 AND THE LEFT SIDE |
| | ELEVATION ON A5 SHOWS A 2650 SH WINDOW. |
| | PLEASE CORRECT. |
| | |
| | 4) THE MINIMUM SIZE FOR ATTIC ACCESS IS |
| | 20"X 36" PER FBC 2309.6. PLEASE REVISE |
| | DIMENSIONS ON THE PLAN. |
| | |
| | 5) PROVIDE AT LEAST ONE FULL BATHROOM |
| | WITH A DOOR THAT HAS A 29" CLEAR OPENING |
| | AS REQUIRED BY FBC CHAPTER 11. A 32" |
| | WIDE DOOR IS NEEDED. |
| | |
| | 6) THE INFORMATION SUBMITTED FOR THE |
| | GAS BBQ IS NOT ADEQUATE. THE PRODUCT |
| | LISTING AND SPECS ARE REQUIRED. |
| | |
| | 7) THE FOOTPRINT OF THE STRUCTURE ON THE |
| | SURVEY DOES NOT MATCH THE PLANS. SUBMIT |
| | A REVISED SURVEY. |
| | |
| | 8) PROVIDE DETAILS (DRAWINGS) OF THE |
| | CUSTOM WALL BRACKETS (ID# 4,4A & 4B) |
| | SPECIFIED IN THE CONNECTOR SCHEDULE ON |
| | S3. |
| | |
| | 9) SPECIFY THE MAXIMUM UPLIFT CAPACITY |
| | OF THE STEEL COLUMN ON SHEET S4. |
| | |
| | 10) SOME OF THE ADJUSTMENT COEFFICIENTS |
| | FOR EXPOSURE B HAVE INCORRECT VALUES IN |
| | THE TABLE ON SHEET S4. |
| | |
| | 11) PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SUBMIT |
| | PRODUCT APPROVALS FOR THE FOLLOWING: |
| | - ONE HOUR FIRE RATED GLASS BLOCK |
| | - SINGLE HUNG WINDOWS |
| | - FIXED GLASS WINDOWS |
| | - ARCHED TOP WINDOWS |
| | - MULLIONS |
| | - OVERHEAD GARAGE DOORS |
| | - DOUBLE INSWING ENTRY DOORS |
| | - EXTERIOR PANEL DOOR |
| | - SLIDING GLASS DOORS |
| | - TRUSS CONNECTORS |
| | - HURRICANE PANELS |
| | |
| | 22) IN ADDITION TO THE PRODUCT APPROVALS |
| | FOR THE HURRICANE PANELS, SUBMIT KEY |
| | PLANS AND INSTALLATION SCHEDULES. |
| | SPECIFY THE MOUNT TYPE, FASTENER TYPE |
| | AND FASTENER SPACING. |
| | |
| | 23) A SEPARATE PERMIT WILL BE REQUIRED |
| | FOR ROOFING. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |