Plan Review Notes
Plan Review Notes For Permit 03120908
Permit Number 03120908
Review Stop B
Sequence Number 1
Notes
Date Text
2003-12-30 00:00:00****CORRECTIONS*****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)A SEPARATE PERMIT IS REQUIRED FOR
 THE REPLACEMENT OF THE AWNING FABRIC.
  
 2.)A HANDRAIL IS REQUIRED ON BOTH
 SIDES OF THE RAMP, FBC11-4.8.5.THE
 CLEAR SPACE BETWEEN THE HANDRAIL AND THE
 WALL SHALL BE 1 1/2".TOP OF HANDRAIL
 GRIPPING SURFACES SHALL BE MOUNTED
 BETWEEN 34-38" (PLAN SHOWS 44").
  
 3.)THE DRINKING FOUNTAIN IS TO COMPLY
 WITH FBC11-4.1.3(10).
  
 4.)PROVIDE A STRUCTURAL DETAIL FOR THE
 SUSPENDED CEILINGS.
  
 5.)PROVIDE MORE INFORMATION ABOUT
 THE GLAZING (REPLACING STOREFRONT GLASS
 WITH CLEAR).DESCRIBE EXISTING AND
 PROPOSED, ADDRESSING IMPACT PROTECTION
 AND DESIGN PRESSURES.
  
 6.)NOTE HOW THE RAMP AND RAISED AREA
 WILL BE CONSTRUCTED.
  
 7.)PROVIDE A WALL SECTION FOR THE
 INTERIOR PARTITION WALLS.
  
 8.)THE DOOR SHOWN AT THE OFFICE
 BLOCKS THE EGRESS, FBC1012.1.4.
  
 9.)THE PERMIT APPLICATION STATES
 "FRAMING ONLY"; THE PLANS INCLUDE
 OTHER TRADES.
  
 10.)INDICATE THE BATHROOM AND MOP
 SINK AS EITHER NEW OR EXISTING.IT IS
 NOT CLEAR ON THE PLAN.
  
 11.)NOTE - THIS IS A PARTIAL REVIEW,
 AS PER CONTRACTOR'S REQUEST 1/5/04.
 PLANS ARE INCOMPLETE; WILL PERFORM A
 COMPLETE REVIEW WHEN PLANS CONTAIN
 SUFFICIENT INFORMATION.