| Date |
Text |
| 2004-04-27 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 03120833 |
| | ADD: 314 CLEMATIS ST |
| | CONT:SHAWE-AGER CONSTRUCTION |
| | TEL: (561)248-6411 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | 3RD REVIEW |
| | ACTION: DENIED |
| | |
| | 1) COMMENT# 1 FROM FIRST REVIEW: |
| | SHEET A2.1 SHOWS THE RECONFIGURATION OF |
| | THE FRONT ENTRY STAIR. |
| | 1006.1.1 EXIT STAIRWAYS BETWEEN FLOORS |
| | SHALL BE ENCLOSED IN OR SEPERATED BY |
| | FIRE RESISTANCE CONSTRUCTION IN ACCORD- |
| | ANCE WITH 705.2AND TABLE 705.1.2. |
| | |
| | THE ISSUE NOT BEING ADDRESSED ON THE |
| | FRONT EXIT STAIRWAY FROM PREVIOUS |
| | REVIEWS IS THERE ARE (2) REQUIRED MEANS |
| | OF EGRESS, THE STAIRWAY SHAFT OR STAIR |
| | ENCLOSURE,(EXIT) 1006.1.4 THERE SHALL |
| | BENO ENCLOSED USABLE SPACE WITHIN AN |
| | EXIT ENCLOSURE. 1006.1.3 A STAIRWELL |
| | ENCLOS- URE SHALL NOT BE USED FOR ANY |
| | OTHER PUR-POSE OTHER THAN A MEANS OF |
| | EGRESS. |
| | OPENINGS IN EXIT ENCLOSURES OTHER THAN |
| | UNEXPOSED EXTERIOR OPENINGS SHALL BE |
| | LIMITED TO THOSE NECESSARY FOR THE EXIT |
| | ACCESS TO THE ENCLOSURE FROM NORMALLY |
| | OCCUPIABLE OR HABITABLE ROOMS AND FOR |
| | EGRESS FROM THE ENCLOSURE. |
| | |
| | 2) COMMENT# 4 FROM 1ST REVIEW: |
| | PRIVATE BATHROOMS, 11-4.1.3(11) PRIVATE |
| | BATHROOMS ARE TO BE ADAPTABLE. THIS |
| | WILL MEAN TO BE ADAPTABLE THE 5'-0" |
| | TURNING RADIUS IS IN AFFECT, BATHROOM |
| | 235 APPEARS TO MAKE THIS REQUIREMENT |
| | INDICATE THE 5'-0" CLEAR TURNING RADIUS |
| | FOR BATHROOM 210. PROVIDE THE REQUIRED |
| | BACKING FOR AN ADAPTABLE BATHROOM |
| | (11-4.16.4) BACKING FOR GRAB BARS. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |