Plan Review Notes
Plan Review Notes For Permit 03120608
Permit Number 03120608
Review Stop B
Sequence Number 1
Notes
Date Text
2003-12-22 00:00:00DENIED
 SHOW LEDGER FASTENING DETAIL, POST
 DETAIL. JOIST SIZE, SPACING AND JOIST
 HANGER USED.TYPES OF MATERIALS USED
 AND SIZE.SHOW STAIR DETAIL.
 2304.3.4 WOOD JOIST SHALL HAVE 18"
 CLEARENCE FROM THE BOTTOM OF JOIST TO
 EARTH OR ELSE BE PRESSURE TREATED WOOD.
 2304.2.2 ALL POST POLES AND
 COLUMNS SUPPORTING PERMANENT STRUCTURES
 AND EMBEDDED IN CONCRETE WHICH IS IN
 CONTACT WITH THE GROUND SHALL BE
 APPROVED PRESERVATIVE-TREATED WOOD
 SUITABLE FOR GROUND CONTACT USE.
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672