| 2004-06-19 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 03120591 |
| | ADD: 533 CLEMATIS ST |
| | CONT: SHAKMAN CONSTRUCTION |
| | TEL: (561)756-0540 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | 2ND REVIEW |
| | ACTION: DENIED |
| | |
| | NOTE: THIS REVIEW IS THE RESULTS OF A |
| | MEETING WITH SHERRY PILAND/ NEIL MELICK |
| | AS TO WHAT PARTS OF THE BUILDING WILL |
| | FALL UNDER THE HISTORIC PERVIEW AND |
| | WHAT |
| | PARTS WILL FALL UNDER BUILDING FOR |
| | REVIEW. |
| | |
| | 1) COMMENT# 4 FROM PREVIOUS REVIEW: |
| | 903.8.1 BUILDINGS 3 STORIES OR MORE. |
| | ANY |
| | BUILDING 3 STORIES SHAL BE EQUIPPED |
| | WITH |
| | AN APPROVED AUTOMATIC FIRE SPRINKLER |
| | SYSTEM INSTALLED IN ACCORDANCE WITH |
| | 903.1 |
| | RESPONCE: EXISTING SYSTEM, GC TO SUBMIT |
| | FIRE SPRINKLER DRAWINGS AS PART OF THIS |
| | SUBMITTAL. |
| | NO FIRE SPRINKLER PLANS WERE SUBMITTED! |
| | |
| | 2) COMMENT# 14 FROM PREVIOUS REVIEW: |
| | FL BLD CODE 1606.1.5: COMPONENTS & |
| | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| | OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| | TESTING REPORTS,MISSING REPORTS ARE AS |
| | FOLLOWS: STOREFRONT SYSTEM |
| | RESPONCE: GC SHALL SUBMIT THE TEST |
| | REPORTS REQUIRED FOR THESES ITEMS. |
| | NO PRODUCT TESTING REPORTS SUBMITTED. |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, |
| | 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR |
| | INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 3) COMMENT #20 FROM PREVIOUS REVIEW |
| | DEALS WITH REINFORCED AREAS FOR |
| | ADAPTABLE BATHROOMS THERE IS NO |
| | INFORMA- |
| | TION FOR BACKING FOR THE SHOWER, TAKEN |
| | FROM FLORIDA ACCESSIBILITY CODE AND THE |
| | FAIR HOUSING CODE. |
| | |
| | 4) COMMENT #21 FROM PREVIOUS REVIEW: |
| | DEALS WITH THE FIRST FLOOR ENTRY DOORS. |
| | SHEET A-0 INDICATES THAT THERE IS A |
| | 2'-6" SET BACK, SHEET A2.1 INDICAES A |
| | PAIR OF 3'-0" OVERHANGING INTO THE |
| | RIGHT OF WAY 6". |
| | |
| | 5) GUIDELINES FOR REHABILITING HISTORIC |
| | BUILDINGS, FLORIDA BUILDING CODE,APPX. |
| | D |
| | THE SAME MEETING BETWEEN NEIL MELICK, |
| | SHERRY PILAND AND MYSELF, IT WAS |
| | DISCUSS |
| | ED THAT THE WINDOWS WOULD NOT BE |
| | REPLACED, HISTORIC RECOMMENDATIONS. THE |
| | TOPIC OF ENERGY RETROFITTING WAS |
| | DISCUSS |
| | ED. SINCE THE WINDOWS WERE NOT TO BE |
| | RE- |
| | PLACED IT WAS DETERMINED TO HELP MAKE |
| | THE BUILDING MORE ENERGY EFFICIENT AND |
| | WORK ING WITH THE EXISTING WINDOWS, TO |
| | IMPROVE THERMAL EFFICIENCY WITH |
| | WEATHER- |
| | STRIPPING, CAULKING, INTERIOR SHADES, |
| | AND IF HISTORICLLY APPROPRIATE, BLINDS |
| | AND AWNINGS. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |