2005-08-02 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03120591
 ADD: 533 CLEMATIS ST.
 CONT: SHAKMAN
 TEL: (561)239- 9018
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 SUBMITTAL SHOP DRAWINGS REVIEW
 ACTION: REVIEWED/ PROVISO
 AUGUST 02/05
 1) PLANS DO NOT INDICATE THE SIZE OF THE
 FORMED BY THE TRIANGULAR AREA FORMED BY
 THE TREAD, RISER AND BOTTOM OF GUARD
 RAIL. 1015.6 (1)A 6 INCH (152 MM)
 SPHERE SHALL NOT PASS THROUGH THE
 TRIANGULAR OPENING FORMED BY A TREAD,
 RISER AND BOTTOM OF A GUARDRAIL.
  
 2) PLANS DO NOT INDICATE HANDRAILS OR
 EXTENTIONS: 11-4.9.4(2) IF HANDRAILS ARE
 NOT CONTINUOUS, THEY SHALL EXTEND AT
 LEAST 12 INCHES (305 MM) BEYOND THE
 TOP RISER AND AT LEAST 12 INCHES
 (305 MM) PLUS THE WIDTH OF ONE TREAD
 BEYOND THE BOTTOM RISER.AT THE
 TOP, THE EXTENSION SHALL BE PARALLEL
 WITH THE FLOOR OR GROUND SURFACE.
 AT THE BOTTOM, THE HANDRAIL SHALL
 CONTINUE TO SLOPE FOR A DISTANCE OF
 THE WIDTH OF ONE TREAD FROM THE
 BOTTOM RISER; THE REMAINDER OF THE
 EXTENSION SHALL BE HORIZONTAL (SEE
 FIGURE 11-19(C) AND
 FIGURE 11-19(D)).HANDRAIL
 EXTENSIONS SHALL COMPLY WITH 11-4.4.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026